Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC+PET Makroblend® UT403 Covestro - Polycarbonates
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 124 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 98.0 °C | |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 7E-05 cm/cm/°C |
| TD:23to55°C | ISO 11359-2 | 8E-05 cm/cm/°C | |
| thermal conductivity | 23°C | ISO 8302 | 0.20 W/m/K |
| Vicat softening temperature | ISO 306/B120 | 139 °C |
| mechanical properties | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| Bending modulus | 23°C | ISO 178 | 2300 MPa |
| bending strength | 3.5%Strain,23°C | ISO 178 | 72.0 MPa |
| 23°C | ISO 178 | 86.0 MPa | |
| Nominal tensile fracture strain | 23°C | ISO 527-2/50 | 100 % |
| Tensile modulus | 23°C | ISO 527-2/1 | 2400 MPa |
| Tensile strain | Yield,23°C | ISO 527-2/50 | 5.0 % |
| tensile strength | Break,23°C | ISO 527-2/50 | 58.0 MPa |
| Yield,23°C | ISO 527-2/50 | 58.0 MPa |
| Electrical performance | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 3 |
| Dielectric strength | 23°C,1.00mm | IEC 60243-1 | 34 kV/mm |
| Dissipation factor | 23°C,100Hz | IEC 60250 | 1.7E-03 |
| 23°C,1MHz | IEC 60250 | 0.015 | |
| Relative permittivity | 23°C,1MHz | IEC 60250 | 3.10 |
| 23°C,100Hz | IEC 60250 | 3.20 | |
| Surface resistivity | IEC 60093 | 1E+16 ohms | |
| Volume resistivity | 23°C | IEC 60093 | 1E+16 ohms·cm |
| Physical properties | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| density | 23°C | ISO 1183 | 1.23 g/cm³ |
| Melt Volume Flow Rate (MVR) | 270°C/5.0kg | ISO 1133 | 34.0 cm³/10min |
| Outdoor applicability | UL 746C | f1 | |
| Shrinkage rate | TD | ISO 2577 | 0.60to0.80 % |
| MD | ISO 2577 | 0.60to0.80 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 % |
| Saturation,23°C | ISO 62 | 0.50 % |
| impact performance | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 7391 | 20 kJ/m² |
| 23°C | ISO 7391 | 70 kJ/m² |
| flammability | Test Condition | Test Method | Covestro - Polycarbonates/Makroblend® UT403 |
|---|---|---|---|
| UL flame retardant rating | 3.0mm | UL 94 | HB |
| 1.5mm | UL 94 | HB |