Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PET Plaslube® PC / PET IM 1012 Techmer Polymer Modifiers
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
Impact strength of cantilever beam gap | -40°C,3.18mm | ASTM D256 | 430 J/m |
Dart impact | 23°C,TotalEnergy | ASTM D3763 | 5.12 J |
-40°C,TotalEnergy | ASTM D3763 | 4.87 J | |
Impact strength of cantilever beam gap | 23°C,3.18mm | ASTM D256 | 800 J/m |
hardness | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
Rockwell hardness | R级 | ASTM D785 | 117 |
Electrical performance | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
Volume resistivity | ASTM D257 | 1E+15 ohms·cm | |
dielectric strength | ASTM D149 | 28 kV/mm |
Mechanical properties | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
elongation | 屈服 | ASTM D638 | 110 % |
Flexural modulus | ASTM D790 | 2340 MPa | |
tensile strength | 屈服 | ASTM D638 | 55.2 MPa |
bending strength | ASTM D790 | 91.0 MPa |
flammability | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
UL flame retardant rating | UL 94 | HB |
physical property | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
melt mass-flow rate | 265°C/5.0kg | ASTM D1238 | 12 g/10min |
285°C/2.16kg | ASTM D1238 | 28 g/10min | |
Water absorption rate | 24hr | ASTM D570 | 0.17 % |
density | ASTM D792 | 1.22 g/cm³ |
Thermal performance | Test Condition | Test Method | Techmer Polymer Modifiers/Plaslube® PC / PET IM 1012 |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ASTM D648 | 116 °C |
Linear coefficient of thermal expansion | MD | ASTM D696 | 6.3E-05 cm/cm/°C |
Contact Us
Get App
Top