Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC HPX4 1H8A005T SABIC INNOVATIVE US
LEXAN™
Drug application、Medical devices、Medical and nursing suppl
Middle flow、Biocompatibility、Steam sterilization
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Thermal Properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Heat Deflection Temperature | 1.8MPa,Unannealed,64.0mmSpan | ISO75-2/Af | 119 °C |
RTIElec | UL746 | 130 °C | |
Vicat Softening Temperature | -- | ISO306/B50 | 141 °C |
Linear thermal expansion coefficient | TD:-40to95°C | ASTME831 | 7.9E-05 cm/cm/°C |
Ball PressureTest | 125°C | IEC60695-10-2 | Pass |
Heat Deflection Temperature | 1.8MPa,未退火,3.20mm | ASTMD648 | 124 °C |
RTIStr | UL746 | 130 °C | |
Vicat Softening Temperature | ASTMD152510 | 141 °C | |
-- | ISO306/B120 | 142 °C | |
Linear thermal expansion coefficient | MD:-40到95°C | ASTME831 | 7.2E-05 cm/cm/°C |
MD:23到80°C | ISO11359-2 | 7.2E-05 cm/cm/°C | |
TD:23to80°C | ISO11359-2 | 7.9E-05 cm/cm/°C |
Hardness | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Rockwell Hardness | L计秤 | ASTMD785 | 90 |
Physical | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Moisture Absorption | 平衡,23°C,50%RH | ISO62 | 0.093 % |
Modeling Shrinkage | MD:3.20mm | 内部方法 | 0.40to0.80 % |
Melt Mass-Flow Rate | 300°C/1.2kg | ASTMD1238 | 10 g/10min |
Modeling Shrinkage | TD:3.20mm | 内部方法 | 0.40to0.80 % |
Melt Volume flow Rate | 300°C/1.2kg | ISO1133 | 9.50 cm3/10min |
Moisture Absorption | 饱和,23°C | ISO62 | 0.12 % |
Mechanical Properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Flexural Modulus | 50.0mm跨距 | ASTMD790 | 2220 Mpa |
Tensile Stress | 断裂 | ISO527-2/50 | 61.5 Mpa |
Tensile Elongation | 断裂 | ASTMD638 | 130 % |
Tensile Strain | 断裂 | ISO527-2/50 | 120 % |
Tensile Modulus | ISO527-2/1 | 2350 Mpa | |
Tensile Strength | 屈服 | ASTMD638 | 58.0 Mpa |
Flexural Modulus | ISO178 | 2150 Mpa | |
Flexural Strength | 屈服,50.0mm跨距 | ASTMD790 | 94.3 Mpa |
Tensile Elongation | 屈服 | ASTMD638 | 5.8 % |
Tensile Stress | 屈服 | ISO527-2/50 | 57.9 Mpa |
Tensile Strain | 屈服 | ISO527-2/50 | 5.5 % |
Flexural Strength | ISO178 | 90.2 Mpa | |
Tensile Modulus | ASTMD638 | 2220 Mpa | |
Tensile Strength | 断裂 | ASTMD638 | 64.1 Mpa |
Optical | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Transmittance | 2540µm | ASTMD1003 | 82.0 % |
Haze | 2540µm | ASTMD1003 | 3.0 % |
Impact Properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Notched Izod Impact Strength | -30°C | ISO180/1A | 55 kJ/m² |
Instrumented Dart Impact | -30°C,TotalEnergy | ASTMD3763 | 85.0 J |
Charpy Unnotched Impact Strength | -30°C | ISO179/1eU | NoBreak |
Unnotched Izod Impact Strength | -30°C | ISO180/1U | NoBreak |
Charpy Notched Impact Strength | -30°C | ISO179/1eA | 55 kJ/m² |
Instrumented Dart Impact | 23°C,TotalEnergy | ASTMD3763 | 82.4 J |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 65 kJ/m² |
Charpy Unnotched Impact Strength | 23°C | ISO179/1eU | NoBreak |
Unnotched Izod Impact Strength | 23°C | ISO180/1U | NoBreak |
Notched Izod Impact Strength | 23°C | ISO180/1A | 65 kJ/m² |
Flammability | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Glow Wire Ignition Temperature | 3.0mm | IEC60695-2-13 | 825 °C |
Flame Rating | 2.5mm | UL94 | V-2 |
Glow Wire Ignition Temperature | 0.8mm | IEC60695-2-13 | 825 °C |
Glow Wire Flammability Index | 3.0mm | IEC60695-2-12 | 960 °C |
Electrical Properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX4 1H8A005T |
---|---|---|---|
Surface Resistivity | ASTMD257 | >1.0E+15 ohms | |
Volume Resistivity | ASTMD257 | >1.0E+15 ohms·cm |
Contact Us