Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

SPS S931 IDEMITSU JAPAN
XAREC™
Household daily necessities,Electrical applications
High temperature resistan,Glass fiber reinforced
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 265 °C |
1.8 MPa, Unannealed | ISO 75-2/A | 230 °C | |
Linear coefficient of thermal expansion | Across Flow : -30 to 30°C | TMA | 4.2E-5 cm/cm/°C |
Flow : -30 to 30°C | TMA | 1.9E-5 cm/cm/°C | |
RTI | UL 746 | 130 °C | |
RTI Elec | UL 746 | 130 °C | |
RTI Imp | UL 746 | 120 °C |
mechanical properties | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
Bending modulus | ISO 178 | 10300 Mpa | |
bending strength | ISO 178 | 170 Mpa | |
Tensile modulus | ISO 527-2 | 10500 Mpa | |
Tensile strain | Break | ISO 527-2 | 1.5 % |
tensile strength | Break | ISO 527-2 | 110 Mpa |
Electrical performance | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
Arc resistance | ASTM D495 | PLC 6 | |
Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
Dielectric constant | 1 MHz | IEC 60250 | 3.00 |
Dielectric strength | ASTM D149 | 35 KV/mm | |
Dissipation factor | 1 MHz | IEC 60250 | 2.0E-3 |
High arc combustion index | 1.5 mm | UL 746 | PLC 0 |
0.75 mm | UL 746 | PLC 0 | |
High voltage arc tracing rate | UL 746 | PLC 3 | |
Hot wire ignition | 0.75 mm | UL 746 | PLC 3 |
1.5 mm | UL 746 | PLC 2 | |
Volume resistivity | IEC 60093 | > 1.0E+16 ohms·cm |
Physical properties | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
density | ISO 1183 | 1.45 g/cm³ | |
Shrinkage rate | Flow | Internal Method | 0.10 - 0.40 % |
横向Flow | Internal Method | 0.30 - 0.70 % | |
Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.020 % |
impact performance | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179 | 9.0 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180 | 8.0 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179 | 28 kJ/m² |
Suspended wall beam without notch impact strength | 23°C | ISO 180 | 26 kJ/m² |
flammability | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
UL flame retardant rating | 0.75 mm | UL 94 | V-0 |
injection | Test Condition | Test Method | IDEMITSU JAPAN/S931 |
---|---|---|---|
drying temperature | 120 °C | ||
drying time | 3.0 to 5.0 hr | ||
Mold temperature | 130 to 155 °C | ||
Processing (melt) temperature | 280 to 310 °C |