Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT XFR6840 GF30 JAPAN POLYPLASTIC
DURANEX®
Electrical applications、Electronic and electrical
Electrical performance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | JAPAN POLYPLASTIC/XFR6840 GF30 |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 |
Basic performance | Test Condition | Test Method | JAPAN POLYPLASTIC/XFR6840 GF30 |
---|---|---|---|
density | ISO 1183 | 1.49 g/cm³ |
Mechanical properties | Test Condition | Test Method | JAPAN POLYPLASTIC/XFR6840 GF30 |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eA | 5.0 kJ/m² | |
Tensile strain | Break | ISO 527-2 | 2.3 % |
tensile strength | Yield | ISO 527-2 | 90.0 MPa |
Flexural modulus | ISO 178 | 7600 MPa | |
bending strength | ISO 178 | 140 MPa |
Electrical performance | Test Condition | Test Method | JAPAN POLYPLASTIC/XFR6840 GF30 |
---|---|---|---|
dielectric strength | 3.00mm | IEC 60243-1 | 20 kV/mm |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V |
Thermal performance | Test Condition | Test Method | JAPAN POLYPLASTIC/XFR6840 GF30 |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 210 °C |