Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC HPX8R NA8A005T SABIC INNOVATIVE US
LEXAN™
Medical field,medical care
High mobility,Easy to demould,Biocompatibility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Rockwell hardness | L-Sale | ASTM D785 | 90 |
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass |
| Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 121 °C |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 118 °C | |
| Linear coefficient of thermal expansion | TD:23to80°C | ISO 11359-2 | 7.4E-05 cm/cm/°C |
| MD:-40to95°C | ASTME831 | 6.5E-05 cm/cm/°C | |
| MD:23to80°C | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
| TD:-40to95°C | ASTME831 | 7.4E-05 cm/cm/°C | |
| RTI Elec | UL 746 | 130 °C | |
| RTI Str | UL 746 | 130 °C | |
| Vicat softening temperature | -- | ISO 306/B120 | 140 °C |
| ASTM D152510 | 138 °C | ||
| -- | ISO 306/B50 | 138 °C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Bending modulus | 50.0mmSpan | ASTM D790 | 2360 Mpa |
| ISO 178 | 2250 Mpa | ||
| bending strength | Yield,50.0mmSpan | ASTM D790 | 99.2 Mpa |
| ISO 178 | 92.9 Mpa | ||
| elongation | Break | ASTM D638 | 120 % |
| Yield | ASTM D638 | 5.8 % | |
| Tensile modulus | ASTM D638 | 2370 Mpa | |
| ISO 527-2/1 | 2400 Mpa | ||
| Tensile strain | Break | ISO 527-2/50 | 120 % |
| Yield | ISO 527-2/50 | 5.4 % | |
| tensile strength | Yield | ASTM D638 | 60.0 Mpa |
| Yield | ISO 527-2/50 | 59.0 Mpa | |
| Break | ISO 527-2/50 | 56.6 Mpa | |
| Break | ASTM D638 | 58.0 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Surface resistivity | ASTM D257 | >1.0E+15 ohms | |
| Volume resistivity | ASTM D257 | >1.0E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 35 g/10min |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 33.0 cm3/10min |
| Shrinkage rate | TD:3.20mm | Internal Method | 0.40-0.80 % |
| MD:3.20mm | Internal Method | 0.40-0.80 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.093 % |
| Saturation,23°C | ISO 62 | 0.12 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 60 kJ/m² |
| -30°C | ISO 179/1eA | 30 kJ/m² | |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 79.0 J |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 30 kJ/m² |
| 23°C | ISO 180/1A | 60 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | NoBreak |
| 23°C | ISO 179/1eU | NoBreak | |
| Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | NoBreak |
| 23°C | ISO 180/1U | NoBreak |
| flammability | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| Burning wire flammability index | 3.0mm | IEC 60695-2-12 | 960 °C |
| Hot filament ignition temperature | 3.0mm | IEC 60695-2-13 | 850 °C |
| 0.8mm | IEC 60695-2-13 | 825 °C | |
| UL flame retardant rating | 1.5mm | UL 94 | HB |
| optical performance | Test Condition | Test Method | SABIC INNOVATIVE US/HPX8R NA8A005T |
|---|---|---|---|
| transmissivity | 2540μm | ASTM D1003 | 82.0 % |
| turbidity | 2540μm | ASTM D1003 | 3.0 % |