Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO FM3020VE-BK1066 SABIC INNOVATIVE JAPAN
NORYL™
medical care
Glass fiber reinforced、Thermal stability、 Structural foaming、fibre、Dimensional stability
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Basic performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/FM3020VE-BK1066 |
---|---|---|---|
Water absorption rate | 24hrs | ASTM D-570 | 0.08 % |
Mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/FM3020VE-BK1066 |
---|---|---|---|
Flexural modulus | 6.4mm | ASTM D-790 | 6546 Mpa |
Impact strength of cantilever beam gap | 23°C | ASTM D-256 | 53 J/m |
Rockwell hardness | ASTM D-785 | 83 | |
tensile strength | 屈伏点3.2mm | ASTM D-638 | 72 Mpa |
bending strength | 6.4mm | ASTM D-790 | 105 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/FM3020VE-BK1066 |
---|---|---|---|
Volume resistivity | ASTM D-257 | 1.0×10 Ω.cm | |
Surface Resistivity | ASTM D-257 | 1.0×10 Ω.cm |
physical property | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/FM3020VE-BK1066 |
---|---|---|---|
enhance | 30 % |
Thermal performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/FM3020VE-BK1066 |
---|---|---|---|
Long term use temperature | 无冲击 | UL 746B | 50 °C |
Heat distortion temperature | 1.8MPa,HDT | ASTM D-648 | 110 °C |
Linear coefficient of thermal expansion | ASTM E-831 | 2.3×10 1/°C | |
Heat distortion temperature | 0.45MPa,HDT | ASTM D-648 | 118 °C |
Long term use temperature | 含冲击 | UL 746B | 50 °C |
电气 | UL 746B | 50 °C |
Contact Us