Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEEK 770GL30 JILIN JOINATURE
ZYPEEK®
Aerospace,Electrical field,Electronic field,Electric wire,Cable,Industrial machinery,Medical supplies,Nursing supplies
enhance,Moderate liquidity,standard,Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | JILIN JOINATURE/770GL30 |
---|---|---|---|
Hot deformation temperature | 1.8 Mpa | ISO 75-f | 328 °C |
Linear coefficient of thermal expansion | 低于Tg沿着Flow | ISO 11359 | 18 ppm/K |
高于Tg沿着Flow | ISO 11359 | 18 ppm/K | |
Melting temperature | ISO 11357 | 343 °C | |
specific heat | 23℃ | DSC | 1.7 kJ/kg /℃ |
Tg (initial) | ISO 11357 | 143 °C | |
thermal conductivity | 23℃ | ISO 22007-4 | 0.3 W/m/K |
mechanical properties | Test Condition | Test Method | JILIN JOINATURE/770GL30 |
---|---|---|---|
Bending modulus | 23℃ | ISO 178 | 11300 Mpa |
bending strength | Break,23℃ | ISO 178 | 265 Mpa |
compressive strength | 23℃ | ISO 604 | 250 Mpa |
Shore hardness | 23℃ | ISO 868 | 88 D 级 |
Tensile strain | Break,23℃ | ISO 527 | 2.7 % |
tensile strength | Break,23℃ | ISO 527 | 175 Mpa |
Electrical performance | Test Condition | Test Method | JILIN JOINATURE/770GL30 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 4 | |
Dielectric constant | 23 ℃, 1 kHz | IEC 60250 | 3.2 |
Dielectric strength | 2 mm | IEC 60243-1 | 25 KV/mm |
Dissipation factor | 23℃,1 MHz | IEC 60250 | 0.005 |
Volume resistivity | 23 ℃,1V | IEC 60093 | 10^16 ohms·cm |
Physical properties | Test Condition | Test Method | JILIN JOINATURE/770GL30 |
---|---|---|---|
density | 结晶 | ISO 1183 | 1.51 g/cm³ |
melt mass-flow rate | 380℃,5.0kg | ISO 1133 | 4.5 g/10min |
Shrinkage rate | MD | ISO 294-4 | 0.8 % |
TD | ISO 294-4 | 0.3 % | |
Water absorption rate | 23℃,24hr,3.2 mm厚拉伸棒 | ISO 62-1 | 0.04 % |
Equilibrium,23℃ | ISO 62-1 | 0.3 % |
impact performance | Test Condition | Test Method | JILIN JOINATURE/770GL30 |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179-1eA | 8 kJ/m² | |
Impact strength of cantilever beam gap | ISO 180/A | 10 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1U | 55 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180/U | 60 kJ/m² |