plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
TPE 5526 DUPONT USA
Hytrel® 
Automotive sector,Electrical appliances,Fitness equipment,Electronic field,Electrical field
Weather resistance,UV resistance,High mobility,Thermal stability
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodDUPONT USA/5526
Shore hardnessShoreDISO 86855
ShoreD,15SecISO 86851
Supplementary InformationTest ConditionTest MethodDUPONT USA/5526
OdorVDA2705.00
thermal performanceTest ConditionTest MethodDUPONT USA/5526
Brittle temperatureISO 974-98.0 °C
Glass transition temperatureISO 11357-2-20.0 °C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B65.0 °C
1.8MPa,UnannealedISO 75-2/A45.0 °C
Linear coefficient of thermal expansionTD:-40to23°CISO 11359-21.7E-04 cm/cm/°C
MD:--ISO 11359-22E-04 cm/cm/°C
MD:-40to23°CISO 11359-21.8E-04 cm/cm/°C
TD:--ISO 11359-22E-04 cm/cm/°C
TD:EffectiveThermalDiffusivityISO 11359-29E-08 m²/s
Melting temperatureISO 11357-3203 °C
Vicat softening temperature--ISO 306/B5075.0 °C
--ISO 306/A50180 °C
mechanical propertiesTest ConditionTest MethodDUPONT USA/5526
Bending modulusISO 178200 Mpa
Nominal tensile fracture strainISO 527-2780 %
Tensile creep modulus1hrISO 899-1170 Mpa
1000hrISO 899-1130 Mpa
Tensile modulusISO 527-2190 Mpa
Tensile strainYieldISO 527-235 %
BreakISO 527-2>300 %
tensile strength5.0%StrainISO 527-26.90 Mpa
10%StrainISO 527-211.0 Mpa
BreakISO 527-240.0 Mpa
50%StrainISO 527-214.0 Mpa
YieldISO 527-215.0 Mpa
Wear resistanceISO 4649120 mm³
Electrical performanceTest ConditionTest MethodDUPONT USA/5526
Compared to the anti leakage trace indexIEC 60112 V
Dielectric strengthIEC 60243-120 KV/mm
Dissipation factor1MHzIEC 602500.038
100HzIEC 602509E-03
Relative permittivity100HzIEC 602504.90
1MHzIEC 602504.60
Surface resistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 600934E+13 ohms·cm
Physical propertiesTest ConditionTest MethodDUPONT USA/5526
densityISO 11831.19 g/cm³
MediumDensity1.04 g/cm³
melt mass-flow rateISO 113318 g/10min
Melt Volume Flow Rate (MVR)220°C/2.16kgISO 113317.5 cm3/10min
Shrinkage rateMDISO 294-41.4 %
TDISO 294-41.4 %
SpecificHeatCapacity of Melt2110 J/kg/°C
ThermalConductivityofMelt0.19 W/m/K
Water absorption rateEquilibrium,23°C,2.00mm,50%RHISO 620.20 %
23°C,24hrISO 620.60 %
Saturation,23°C,2.00mmISO 620.60 %
impact performanceTest ConditionTest MethodDUPONT USA/5526
Charpy Notched Impact Strength-30°C,Partial BreakISO 179/1eA150 kJ/m²
23°CISO 179/1eANoBreak
-40°CISO 179/1eA30 kJ/m²
Impact strength of cantilever beam gap23°CISO 8256/1270 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
23°CISO 179/1eUNoBreak
flammabilityTest ConditionTest MethodDUPONT USA/5526
Burning rate1.00mmISO 379528 mm/min
Extreme Oxygen IndexISO 4589-221 %
FMVSS flammabilityFMVSS302SE/B
Fogging-G-valuecondensateISO 64521E-04 g
UL flame retardant rating3.0mmIEC 60695-11-10,-20HB
3.0mmUL 94HB
1.5mmIEC 60695-11-10,-20HB
1.5mmUL 94HB
elastomerTest ConditionTest MethodDUPONT USA/5526
tear strength横向FlowISO 34-1130 kN/m
FlowISO 34-1130 kN/m