Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PC 1239 COVESTRO GERMANY
Makrolon® 
film、Electronic field、Electrical field、Blow molding applications、bottle
high viscosity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodCOVESTRO GERMANY/1239
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
Multi axis Instrumented Impact Energy-30°CISO 6603-260.0 J
Impact strength of simply supported beam without notch23°CISO 179/1eUNoBreak
Charpy Notched Impact Strength-30°C,完全断裂ISO 739120 kJ/m²
Impact strength of cantilever beam gap23°C,局部断裂ISO 739165 kJ/m²
Impact strength of simply supported beam without notch-60°CISO 179/1eUNoBreak
Charpy Notched Impact Strength23°C,局部断裂ISO 739175 kJ/m²
Multi axis Instrumented Impact Energy23°CISO 6603-255.0 J
Multi axis Instrumented Peak Impact Force23°CISO 6603-25500 N
Impact strength of cantilever beam gap-30°C,局部断裂ISO 739155 kJ/m²
Multi axis Instrumented Peak Impact Force-30°CISO 6603-26400 N
hardnessTest ConditionTest MethodCOVESTRO GERMANY/1239
ball-indentation hardnessISO 2039-1108 Mpa
filmTest ConditionTest MethodCOVESTRO GERMANY/1239
Water Vapor Transmission Rate23°C,85%RH,100µmISO 15106-115 g/m²/24hr
GasPermeationNitrogen:23°C,100.0µmISO 2556140 cm³/m²/bar/24hr
CarbonDioxide:23°C,100.0µmISO 25564200 cm³/m²/bar/24hr
Oxygen:23°C,100.0µmISO 2556740 cm³/m²/bar/24hr
Electrical performanceTest ConditionTest MethodCOVESTRO GERMANY/1239
dielectric strength23°C,1.00mmIEC 60243-134 KV/mm
Compared to the Leakage Tracking Index (CTI)解决方案BIEC 60112 V
relative permittivity23°C,1MHzIEC 602503.00
Compared to the Leakage Tracking Index (CTI)解决方案AIEC 60112 V
Volume resistivity23°CIEC 600931E+16 ohms·cm
relative permittivity23°C,100HzIEC 602503.10
Surface ResistivityIEC 600931E+16 ohms
Dissipation Factor23°C,100HzIEC 602501E-03
23°C,1MHzIEC 602500.010
Mechanical propertiesTest ConditionTest MethodCOVESTRO GERMANY/1239
bending strength3.5%Strain,23°CISO 17870.0 Mpa
Bending Strain23°CISO 1787.2 %
tensile strength 屈服,23°CISO 527-2/5064.0 Mpa
bending strength23°CISO 17894.0 Mpa
tensile strength 断裂,23°CISO 527-2/5065.0 Mpa
Tensile strain屈服,23°CISO 527-2/506.6 %
Flexural modulus23°CISO 1782300 Mpa
Tensile modulus23°CISO 527-2/12300 Mpa
Nominal tensile fracture strain23°CISO 527-2/50>50 %
Tensile strain断裂,23°CISO 527-2/50100 %
optical performance Test ConditionTest MethodCOVESTRO GERMANY/1239
transmissivity1000µmISO 13468-288.0 %
2000µmISO 13468-287.0 %
Haze ratio3000µmISO 14782<0.80 %
refractive indexISO 4891.587
transmissivity4000µmISO 13468-284.0 %
flammabilityTest ConditionTest MethodCOVESTRO GERMANY/1239
Burning wire flammability index3.0mmIEC 60695-2-12930 °C
FlashIgnitionTemperatureASTM D1929480 °C
Burning wire flammability index1.5mmIEC 60695-2-12900 °C
Hot filament ignition temperature3.0mmIEC 60695-2-13900 °C
1.5mmIEC 60695-2-13900 °C
Limiting Oxygen IndexISO 4589-226 %
Burning wire flammability index0.75mmIEC 60695-2-12900 °C
SelfIgnitionTemperatureASTM D1929550 °C
Hot filament ignition temperature0.75mmIEC 60695-2-13900 °C
physical property Test ConditionTest MethodCOVESTRO GERMANY/1239
density23°CISO 11831.20 g/cm³
Shrinkage rateMD:2.00mmISO 294-40.75 %
Apparent densityISO 600.66 g/cm³
Water absorption rate平衡,23°C,50%RHISO 620.12 %
Melt volume flow rate300°C/1.2kgISO 11332.00 cm3/10min
Water absorption rate饱和,23°CISO 620.30 %
Shrinkage rateTD:2.00mmISO 294-40.80 %
melt mass-flow rate300°C/1.2kgISO 11332.5 g/10min
Thermal performanceTest ConditionTest MethodCOVESTRO GERMANY/1239
vicat--ISO 306/B120151 °C
Linear coefficient of thermal expansionMD:23到55°CISO 11359-27E-05 cm/cm/°C
Heat distortion temperature0.45MPa,未退火,HDTISO 75-2/B145 °C
thermal conductivity23°CISO 83020.20 W/m/K
Linear coefficient of thermal expansionTD:23to55°CISO 11359-27E-05 cm/cm/°C
Heat distortion temperature1.8MPa,未退火,HDTISO 75-2/A132 °C
vicat--ISO 306/B50150 °C
ball-indentation hardness144°CIEC 60695-10-2Pass
Glass Transition TemperatureISO 11357-2152 °C

Contact Us

Get App

Top