hardness | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Rockwell hardness | M-Sale | ISO 2039-2 | 92 |
R-Sale | ISO 2039-2 | 120 |
Supplementary Information | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Emission | VDA275 | <8.00 mg/kg | |
EmissionofOrganicCompounds | VDA277 | 4.30 µgC/g |
thermal performance | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
AnnealingTemperature | 160 °C | ||
AnnealingTime-Optional | 30.0 min/mm | ||
Effective thermal diffusivity coefficient | 8E-08 m²/s | ||
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 162 °C |
1.8MPa,Unannealed | ISO 75-2/A | 94.0 °C | |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1.2E-04 cm/cm/°C |
MD:23to55°C | ASTME831 | 1E-04 cm/cm/°C | |
MD | ISO 11359-2 | 1.2E-04 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 178 °C | |
Vicat softening temperature | ISO 306/B50 | 160 °C |
mechanical properties | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Bending modulus | ISO 178 | 3000 Mpa | |
Friction coefficient | vs.Itself-Dynamic,1hr | ASTM D1894 | 0.25 |
Nominal tensile fracture strain | ISO 527-2 | 23 % | |
Tensile creep modulus | 1hr | ISO 899-1 | 2800 Mpa |
1000hr | ISO 899-1 | 1500 Mpa | |
Tensile modulus | ISO 527-2 | 3300 Mpa | |
Tensile strain | Yield | ISO 527-2 | 12 % |
tensile strength | Yield | ISO 527-2 | 71.0 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 0 | |
Hot wire ignition | 0.750mm | UL 746 | PLC 4 sec |
Relative permittivity | 100Hz | IEC 60250 | 3.80 |
1MHz | IEC 60250 | 3.80 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | IEC 60093 | 1E+14 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
density | ISO 1183 | 1.42 g/cm³ | |
melt mass-flow rate | ISO 1133 | 25 g/10min | |
Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 21.0 cm3/10min |
Shrinkage rate | MD | ISO 294-4 | 1.9 % |
TD | ISO 294-4 | 1.9 % | |
Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.40 % |
Saturation,23°C,2.00mm | ISO 62 | 1.4 % |
impact performance | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0 kJ/m² |
-30°C | ISO 179/1eA | 7.0 kJ/m² | |
Impact strength of cantilever beam gap | -40°C | ISO 180/1A | 8.0 kJ/m² |
23°C | ISO 180/1A | 7.0 kJ/m² | |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 200 kJ/m² |
23°C | ISO 179/1eU | 200 kJ/m² |
flammability | Test Condition | Test Method | DUPONT THAILAND/900P |
---|---|---|---|
Atomization | G-value(condensate) | ISO 6452 | 2E-04 g |
F-value(refraction) | ISO 6452 | 95 % | |
Burning rate | 1.00mm | ISO 3795 | 20 mm/min |
Extreme Oxygen Index | ISO 4589-2 | 23 % | |
FMVSS flammability | FMVSS302 | B | |
UL flame retardant rating | 0.8mm | IEC 60695-11-10,-20 | HB |
1.5mm | IEC 60695-11-10,-20 | HB | |
0.8mm | UL 94 | HB | |
1.5mm | UL 94 | HB |