Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

SPS S131 IDEMITSU JAPAN
XAREC™
Household daily necessities,Electrical applications
High temperature resistan,Glass fiber reinforced
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 265 °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 245 °C | |
| Linear coefficient of thermal expansion | Across Flow : -30 to 30°C | TMA | 4.3E-5 cm/cm/°C |
| Flow : -30 to 30°C | TMA | 1.9E-5 cm/cm/°C | |
| RTI | UL 746 | 130 °C | |
| RTI Elec | UL 746 | 130 °C | |
| RTI Imp | UL 746 | 120 °C |
| mechanical properties | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| Bending modulus | ISO 178 | 9300 Mpa | |
| bending strength | ISO 178 | 190 Mpa | |
| Tensile modulus | ISO 527-2 | 9700 Mpa | |
| Tensile strain | Break | ISO 527-2 | 2.1 % |
| tensile strength | Break | ISO 527-2 | 120 Mpa |
| Electrical performance | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
| Dielectric constant | 1 MHz | IEC 60250 | 2.90 |
| Dielectric strength | ASTM D149 | 48 KV/mm | |
| Dissipation factor | 1 MHz | IEC 60250 | 1.0E-3 |
| Volume resistivity | IEC 60093 | > 1.0E+16 ohms·cm |
| Physical properties | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| density | ISO 1183 | 1.25 g/cm³ | |
| Shrinkage rate | Flow | Internal Method | 0.10 - 0.40 % |
| 横向Flow | Internal Method | 0.30 - 0.80 % | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.010 % |
| impact performance | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179 | 12 kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180 | 12 kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 44 kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180 | 39 kJ/m² |
| flammability | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| UL flame retardant rating | 0.75 mm | UL 94 | HB |
| injection | Test Condition | Test Method | IDEMITSU JAPAN/S131 |
|---|---|---|---|
| drying temperature | 120 °C | ||
| drying time | 3.0 to 5.0 hr | ||
| Mold temperature | 130 to 155 °C | ||
| Processing (melt) temperature | 280 to 310 °C |