Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT VX5011-7001 SABIC INNOVATIVE SHANGHAI
VALOX™
chip,Electronic and Electrical Applications
Low warpage,Aging resistance,Filler: Glass fiber reinf,10% filler by weight,10% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| Ball Pressure Test | H358/30 | ISO 2039-1 | 165 Mpa |
| Rockwell hardness | R-Sale | ISO 2039-2 | 122 |
| Supplementary Information | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| Filling material | ASTM D229 | 10 % |
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 175 °C | |
| 0.45MPa, unannealed, 64.0mm span | ISO 75-2/Bf | 135 °C | |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 115 °C | |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 115 °C | |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass |
| Flow: 23 to 150 ° C | 23to150℃ | ISO 11359-2 | 3.9E-05 cm/cm/°C |
| Flow: 23 to 80 ° C | 23to80℃ | ISO 11359-2 | 4E-05 cm/cm/°C |
| Flow: -40 to 40 ° C | ASTME831 | 4E-05 cm/cm/°C | |
| ISO 11359-2 | 3.7E-05 cm/cm/°C | ||
| Horizontal: 23 to 150 ° C | Across Flow, 23to150℃ | ISO 11359-2 | 1.5E-04 cm/cm/°C |
| Horizontal: 23 to 80 ° C | Across Flow, 23to80℃ | ISO 11359-2 | 9E-05 cm/cm/°C |
| Horizontal: -40 to 40 ° C | Across Flow, -40to40℃ | ISO 11359-2 | 7E-05 cm/cm/°C |
| Across Flow, -40to40℃ | ASTME831 | 9E-05 cm/cm/°C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| --10 | ISO 178 | 140 Mpa | |
| --11 | ISO 178 | 130 Mpa | |
| --3 | ASTM D638 | 4600 Mpa | |
| 50.0mm span | ASTM D790 | 3600 Mpa | |
| --9 | ISO 178 | 4000 Mpa | |
| crack | ASTM D638 | 90.0 Mpa | |
| ISO 527-2/5 | 95.0 Mpa | ||
| ASTM D638 | 3.0 % | ||
| ISO 527-2/5 | 3.0 % | ||
| Fracture bending strain | ISO 178 | 5.0 % | |
| Taber abraser | 1000Cycles,1000g,CS-17Wheel | Internal Method | 54.0 mg |
| yield | ASTM D638 | 3.0 % | |
| ISO 527-2/5 | 3.0 % | ||
| ASTM D638 | 90.0 Mpa | ||
| ISO 527-2/5 | 95.0 Mpa | ||
| Yield, 50.0mm span | ASTM D790 | 126 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| 0.800mm,inOil | ASTM D149 | 29 KV/mm | |
| 0.800mm, in oil | IEC 60243-1 | 29 KV/mm | |
| 1.60mm,inOil | ASTM D149 | 25 KV/mm | |
| 1.60mm, in oil | IEC 60243-1 | 25 KV/mm | |
| 100Hz | 100Hz | IEC 60250 | 0.016 |
| 1MHz | 1MHz | ASTMD150 | 0.014 |
| 3.20mm, inoil | ASTM D149 | 18 KV/mm | |
| 3.20mm, in oil | IEC 60243-1 | 18 KV/mm | |
| 50Hz | 50Hz | IEC 60250 | 9E-03 |
| 60Hz | 60Hz | IEC 60250 | 9E-03 |
| Compared to the anti leakage trace index | -- | IEC 60112 | PLC 3 |
| SolutionB | IEC 60112 | PLC 4 | |
| High arc combustion index | HAI | UL 746 | PLC 0 |
| Hot wire ignition | HWI | UL 746 | PLC 0 |
| Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
| Volume resistivity | ASTMD257 | >1.0E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| density | ASTMD792 | 1.31 g/cm³ | |
| melt mass-flow rate | 266°C/5.0kg | ASTM D1238 | 85 g/10min |
| 265°C/5.0kg | ASTM D1238 | 85 g/10min | |
| 200°C/3.8kg | ASTM D1238 | 18 g/10min | |
| Melt Volume Flow Rate (MVR) | 250°C/2.16kg | ISO 1133 | 18.0 cm3/10min |
| 265°C/5.0kg | ISO 1133 | 75.0 cm3/10min | |
| 250°C/5.0kg | ISO 1133 | 50.0 cm3/10min | |
| Shrinkage rate | TD2 | Internal Method | 0.50-0.90 % |
| MD:3.20mm | Internal Method | 0.40-0.60 % | |
| MD1 | Internal Method | 0.30-0.80 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.10 % |
| Saturation,23°C | ISO 62 | 0.15 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| 0°C | ASTM D256 | 47 J/m | |
| ISO 180/1A | 5.0 kJ/m² | ||
| 23°C | ASTM D256 | 47 J/m | |
| ISO 179/2C | 6.0 kJ/m² | ||
| ISO 179/1eA | 4.0 kJ/m² | ||
| ISO 179/1eU | 40 kJ/m² | ||
| ASTM D4812 | 480 J/m | ||
| ISO 180/1U | 40 kJ/m² | ||
| ISO 180/1A | 6.0 kJ/m² | ||
| -30°C | ASTM D4812 | 470 J/m | |
| ISO 179/1eU | 30 kJ/m² | ||
| ASTM D256 | 47 J/m | ||
| ISO 179/2C | 6.0 kJ/m² | ||
| ISO 180/1A | 5.0 kJ/m² | ||
| ISO 179/1eA | 4.0 kJ/m² | ||
| ISO 179/2U | 40 kJ/m² | ||
| ISO 180/1U | 30 kJ/m² | ||
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 37.0 J |
| Filling analysis | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| Melt viscosity | 260°C,1500sec^-1 | ISO 11443 | 145 Pa·s |
| flammability | Test Condition | Test Method | SABIC INNOVATIVE SHANGHAI/VX5011-7001 |
|---|---|---|---|
| Burning wire flammability index | 3.00mm | IEC 60695-2-12 | 850 °C |
| 1.00mm | IEC 60695-2-12 | 750 °C | |
| Extreme Oxygen Index | ISO 4589-2 | 21 % | |
| UL flame retardant rating | 1.60mm | UL 94 | HB |