Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 K224-LGM35 ENVALIOR JIANGSU
Akulon®
--
Glass fiber reinforced、Lubricity、UV resistance、Mineral reinforcement、Filler: DSM DSM Netherlan
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | ENVALIOR JIANGSU/K224-LGM35 |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 30 kJ/m² |
-30°C | ISO179/1eU | 25 kJ/m² |
Mechanical properties | Test Condition | Test Method | ENVALIOR JIANGSU/K224-LGM35 |
---|---|---|---|
Tensile stress | 断裂 | ISO527-2 | 120 Mpa |
Bending stress | ISO178 | 165 Mpa | |
Tensile modulus | ISO527-2 | 9000 Mpa | |
Flexural modulus | ISO178 | 7700 Mpa | |
Tensile strain | 断裂 | ISO527-2 | 3.0 % |
Electrical performance | Test Condition | Test Method | ENVALIOR JIANGSU/K224-LGM35 |
---|---|---|---|
Surface Resistivity | IEC60093 | -- ohms | |
100Hz | IEC60250 | 3.50 | |
Dissipation Factor | 100Hz | IEC60250 | 5E-03 |
Volume resistivity | IEC60093 | 1E+14 ohms·cm | |
dielectric strength | IEC60243-1 | 35 KV/mm | |
Dissipation Factor | 1MHz | IEC60250 | 0.014 |
1MHz | IEC60250 | 3.30 |
physical property | Test Condition | Test Method | ENVALIOR JIANGSU/K224-LGM35 |
---|---|---|---|
Water absorption rate | 平衡,23°C,50%RH | ISO62 | 1.7 % |
Thermal performance | Test Condition | Test Method | ENVALIOR JIANGSU/K224-LGM35 |
---|---|---|---|
TD | ISO11359-2 | 1E-04 cm/cm/°C | |
0.45MPa,未退火 | ISO75-2/B | 215 °C | |
1.8MPa,未退火 | ISO75-2/A | 205 °C | |
melting temperature | ISO11357-3 | 220 °C | |
MD | ISO11359-2 | 1.8E-05 cm/cm/°C |