Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC/PBT 1731J-1001 SABIC INNOVATIVE JAPAN
CYCOLOY™
medical care,Plastic bag,Gears,Automotive Applications
Chemical resistance,High impact resistance,High mobility,UV resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 93.0 °C |
1.8MPa,Unannealed,6.40mm | ASTM D648 | 107 °C | |
1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 99.0 °C | |
0.45MPa,Unannealed,6.40mm | ASTM D648 | 116 °C | |
Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 7.8E-05 cm/cm/°C |
TD:-40to40°C | ISO 11359-2 | 7.6E-05 cm/cm/°C | |
TD:-40to40°C | ASTME831 | 7.6E-05 cm/cm/°C | |
MD:-40to95°C | ASTME831 | 8.3E-05 cm/cm/°C | |
MD:-40to40°C | ISO 11359-2 | 7.8E-05 cm/cm/°C | |
RTI Elec | UL 746 | 75.0 °C | |
RTI Imp | UL 746 | 75.0 °C | |
RTI Str | UL 746 | 75.0 °C | |
Vicat softening temperature | -- | ISO 306/B120 | 130 °C |
-- | ISO 306/B50 | 127 °C | |
ASTM D152510 | 125 °C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
Bending modulus | 50.0mmSpan | ASTM D790 | 2340 Mpa |
ISO 178 | 2210 Mpa | ||
bending strength | Yield,50.0mmSpan | ASTM D790 | 93.1 Mpa |
ISO 178 | 93.0 Mpa | ||
elongation | Break | ASTM D638 | 100 % |
Yield | ASTM D638 | 5.0 % | |
Tensile modulus | ASTM D638 | 2370 Mpa | |
ISO 527-2/1 | 2330 Mpa | ||
Tensile strain | Break | ISO 527-2/50 | 90 % |
Yield | ISO 527-2/50 | 5.0 % | |
tensile strength | Yield | ASTM D638 | 61.4 Mpa |
Yield | ISO 527-2/50 | 60.0 Mpa | |
Break | ISO 527-2/50 | 58.0 Mpa | |
Break | ASTM D638 | 56.0 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
Arc resistance | ASTM D495 | PLC 5 | |
Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 |
High arc combustion index | HAI | UL 746 | PLC 0 |
High voltage arc tracing rate | HVTR | UL 746 | PLC 2 |
Hot wire ignition | HWI | UL 746 | PLC 2 |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
melt mass-flow rate | 250°C/5.0kg | ISO 1133 | 8.0 g/10min |
250°C/5.0kg | ASTM D1238 | 9.6 g/10min | |
Shrinkage rate | TD:3.20mm | Internal Method | 0.60-0.80 % |
MD:3.20mm | Internal Method | 0.50-0.70 % | |
Specific volume | ASTM D792 | 0.820 cm³/g | |
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.080 % |
Saturation,23°C | ISO 62 | 0.28 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 65 kJ/m² |
Dart impact | -30°C,TotalEnergy | ASTM D3763 | 61.5 J |
23°C,TotalEnergy | ASTM D3763 | 61.1 J | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 16 kJ/m² |
23°C | ISO 180/1A | 59 kJ/m² |
flammability | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/1731J-1001 |
---|---|---|---|
UL flame retardant rating | 1.5mm | UL 94 | HB |