Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

LCP B130 CELANESE USA
VECTRA®
Automotive Applications,Home appliance components
High rigidity,Flame retardant,enhance,Glass fiber reinforced,Low contractility,Filler/Reinforcement Glas,Packing weight of 305,Low shrinkage rate,Good stiffness
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
Limiting Oxygen Index (LOI) | ISO 4589-1-2 | 50 % |
Basic Performance | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
density | ISO 1183 | 1600 kg/m |
thermal performance | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
Combustibility | UL 94 | V-0 | |
Hot deformation temperature | 1.80MPa | ISO 75-1 | 235 °C |
0.45MPa | ISO 75-1 | 250 °C | |
Linear coefficient of thermal expansion | normal | ISO 11359-1 | 0.000013 cm/cm℃ |
parallel | ISO 11359-1 | 3E-06 cm/cm℃ | |
Vicat softening temperature | 50℃/h 50N | ISO 306 | 169 °C |
mechanical properties | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
Bending modulus | 23℃ | ISO 178 | 20000 Mpa |
bending strength | 23℃ | ISO 178 | 300 Mpa |
Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 12.0 KJ/m |
23℃ | ISO 179/1eU | 18.0 KJ/m | |
Fracture strain | ISO 527-1 | 1.0 % | |
Fracture stress | ISO 527-1 | 205 Mpa | |
Impact strength of cantilever beam gap | 23℃ | ISO 180/1A | 14.0 KJ/m |
Rockwell hardness | ISO 2039-2 | 100 M Scale | |
Suspended wall beam without notch impact strength | 23℃ | ISO 180/1U | 15.0 KJ/m |
Tensile creep modulus | 1hr | ISO 899-1 | 16000 Mpa |
1000hr | ISO 899-1 | 14100 Mpa | |
Tensile modulus | ISO 527-1 | 22000 Mpa |
Electrical performance | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
Dielectric loss | 100Hz | IEC 60250 | 0.0100 |
1000Hz | IEC 60250 | 0.0080 | |
Dielectric strength | IEC 60243-1 | 38 KV/mm | |
Relative permittivity | 100Hz | IEC 60250 | 4.00 |
1000Hz | IEC 60250 | 3.50 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | IEC 60093 | 1E+13 ohm.m |
Physical properties | Test Condition | Test Method | CELANESE USA/B130 |
---|---|---|---|
Shrinkage rate | parallel | ISO 2577 | 0.20 % |
normal | ISO 2577 | 0.0 % |