PP PP9074MED EXXONMOBIL USA
ExxonMobil™
Medical devices、Laboratory equipment、Subcutaneous syringe part、Medical packaging、Medical/nursing supplies
Antibacterial properties、high definition、High mobility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
GardnerImpact | 23°C,3.18mm | ASTM D5420 | 23.6 J |
hardness | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
Rockwell hardness | ASTM D785 | 93 |
Mechanical properties | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
Flexural modulus | 1%正割 | ASTM D542 | 1050 Mpa |
elongation | 屈服 | ASTM D638 | 13 % |
tensile strength | 屈服 | ASTM D638 | 32.8 Mpa |
optical performance | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
Haze ratio | ASTM D1003 | 8.6 % |
physical property | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 24 g/10min |
Thermal performance | Test Condition | Test Method | EXXONMOBIL USA/PP9074MED |
---|---|---|---|
Heat distortion temperature | 0.45MPa,未退火,HDT | ASTM D648 | 75.1 °C |