Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 F223-D DSM HOLAND
Akulon®
--
Low viscosity,Medium viscosity
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 160 °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 60.0 °C | |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 1.0E-4 cm/cm/°C |
| Flow | ISO 11359-2 | 9.0E-5 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 220 °C | |
| RTI | 0.75 mm | UL 746 | 65.0 °C |
| 3.0 mm | UL 746 | 65.0 °C | |
| RTI Elec | 0.75 mm | UL 746 | 150 °C |
| 3.0 mm | UL 746 | 150 °C | |
| RTI Imp | 3.0 mm | UL 746 | 65.0 °C |
| 0.75 mm | UL 746 | 65.0 °C |
| mechanical properties | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| Nominal tensile fracture strain | ISO 527-2 | 20 % | |
| Tensile modulus | ISO 527-2 | 3500 Mpa | |
| Tensile strain | Yield | ISO 527-2 | 4.0 % |
| tensile strength | Yield | ISO 527-2 | 85.0 Mpa |
| Electrical performance | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Dielectric strength | IEC 60243-1 | 8.0 KV/mm | |
| Dissipation factor | 100 Hz | IEC 60250 | 6.5E-3 |
| 1 MHz | IEC 60250 | 0.017 | |
| Relative permittivity | 100 Hz | IEC 60250 | 3.40 |
| 1 MHz | IEC 60250 | 3.10 | |
| Volume resistivity | IEC 60093 | 1.0E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| density | ISO 1183 | 1.14 g/cm³ | |
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.1 % |
| Flow | ISO 294-4 | 1.1 % | |
| Water absorption rate | Saturation, 23°C | ISO 62 | 10 % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 2.8 % |
| impact performance | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 5.0 kJ/m² |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 |
| 23°C | ISO 179/1eU | 无断裂 |
| flammability | Test Condition | Test Method | DSM HOLAND/F223-D |
|---|---|---|---|
| Burning wire flammability index | 1.0 mm | IEC 60695-2-12 | 960 °C |
| Flammability level | UL 94 | V-2 |