plas
Log In

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PEKEKK VICTREX® ST™ ST45GL30 VICTREX UK
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Supplementary InformationTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Dissipation factor23°C,TangentIEC 602500.00400
thermal performanceTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Glass transition temperature--9ISO 11357-2169 °C
--8ISO 11357-2162 °C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af380 °C
Linear coefficient of thermal expansionMD:>162°CISO 11359-22.3E-05 cm/cm/°C
TD:<162°CISO 11359-24E-05 cm/cm/°C
TD:>162°CISO 11359-21E-04 cm/cm/°C
MD:<162°CISO 11359-22.1E-05 cm/cm/°C
Melting temperatureISO 11357-3387 °C
thermal conductivity23°C10ISO 22007-40.30 W/m/K
23°C11ISO 22007-40.35 W/m/K
mechanical propertiesTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Bending modulus23°CISO 17811000 MPa
bending strength175°CISO 178120 MPa
275°CISO 17870.0 MPa
125°CISO 178180 MPa
23°CISO 178280 MPa
Compressive stress120°CISO 604190 MPa
200°CISO 60475.0 MPa
250°CISO 60450.0 MPa
23°CISO 604290 MPa
Tensile modulus23°CISO 527-212000 MPa
Tensile strainBreak,23°CISO 527-22.8 %
tensile strengthBreak,125°CISO 527-2130 MPa
Break,175°CISO 527-280.0 MPa
Break,23°CISO 527-2195 MPa
Break,275°CISO 527-250.0 MPa
Electrical performanceTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Compared to the anti leakage trace indexIEC 60112PLC 4
Dielectric constant23°C,1kHzIEC 602503.30
Dielectric strength2.00mmIEC 60243-122 kV/mm
Volume resistivityIEC 600931E+16 ohms·cm
Physical propertiesTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
densityISO 11831.53 g/cm³
Shrinkage rateMDISO 294-40.30 %
TDISO 294-40.90 %
Spiral flow length--4,5Internal Method10.0 cm
--6Internal Method44.0 cm
Water absorption rate100°C,SaturationISO 620.60 %
impact performanceTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Charpy Notched Impact Strength23°CISO 179/1eA9.0 kJ/m²
Impact strength of cantilever beam gap23°CISO 180/A11 kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1U70 kJ/m²
Suspended wall beam without notch impact strength23°CISO 18060 kJ/m²
Filling analysisTest ConditionTest MethodVICTREX UK/VICTREX® ST™ ST45GL30
Melt viscosity420°CISO 11443600 Pa·s