Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

TPV 251-70W232 CELANESE USA
Santoprene™
Electric wire,Cable,Automotive sector,Cable sheath,Flexible cable sheath,Cable sheath,Wire and cable applications,Application in the automotive field,Flexible cable sheath
Flame retardant,dimensional stability ,Low compression deformati,Flexibility at low temper,Recyclable materials,Electrical performance,Aging resistance,heat-resisting,Good colorability,Ozone resistance,Chemical resistance,Fatigue resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
Shore hardness | ShoreA,15Sec,23°C | ISO 868 | 75 |
thermal performance | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
RTI Elec | UL 746 | 90.0 °C | |
RTI Str | 3.0mm | UL 746 | 90.0 °C |
1.5mm | UL 746 | 85.0 °C |
Electrical performance | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 |
Dielectric constant | 23°C,1.98mm | ASTM D150 | 2.50 |
23°C,1.98mm | IEC 60250 | 2.50 | |
Dielectric strength | 23°C,2.00mm | ASTM D149 | 31 KV/mm |
High arc combustion index | HAI | UL 746 | PLC 0 |
High voltage arc tracing rate | PLC | UL 746 | |
HVTR | UL 746 | PLC 2 | |
Hot wire ignition | HWI | UL 746 | PLC 3 |
flammability | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
Extreme Oxygen Index | ASTM D2863 | 26 % | |
ISO 4589-2 | 26 % | ||
UL flame retardant rating | 3.0mm | UL 94 | V-0 |
1.0mm | UL 94 | V-2 | |
1.5mm | UL 94 | V-0 |
elastomer | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
elongation | Break,23°C,Across Flow | ISO 37 | 550 % |
Break,23°C,Across Flow | ASTM D412 | 550 % | |
tensile strength | Break,23°C | ISO 37 | 6.30 Mpa |
Break,23°C,横向Flow | ASTM D412 | 6.30 Mpa | |
Tensile stress | 100%Strain,23°C,横向Flow | ASTM D412 | 2.70 Mpa |
100%Strain,23°C,横向Flow | ISO 37 | 2.70 Mpa |
aging | Test Condition | Test Method | CELANESE USA/251-70W232 |
---|---|---|---|
Change rate of tensile strength in air | 150°C,168hr | ASTM D573 | -21 % |
150°C,168hr | ISO 188 | -21 % | |
Change rate of ultimate elongation in air | 150°C,168hr | ASTM D573 | -25 % |