Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPA+PA DENYL HT 2010 Y VAMP TECH ITALY
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | VAMP TECH ITALY/DENYL HT 2010 Y |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/A | 5.0 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180 | 25 kJ/m² |
Electrical performance | Test Condition | Test Method | VAMP TECH ITALY/DENYL HT 2010 Y |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
Surface Resistivity | ASTM D257 | 1E+13 ohms |
Mechanical properties | Test Condition | Test Method | VAMP TECH ITALY/DENYL HT 2010 Y |
---|---|---|---|
elongation | 断裂 | ASTM D638 | 1.5 % |
Tensile modulus | ASTM D638 | 7800 MPa | |
tensile strength | 屈服 | ASTM D638 | 110 MPa |
physical property | Test Condition | Test Method | VAMP TECH ITALY/DENYL HT 2010 Y |
---|---|---|---|
Shrinkage rate | MD | ASTM D955 | 0.45 % |
Water absorption rate | 饱和 | ASTM D570 | 0.40 % |
density | ASTM D792 | 1.33 g/cm³ | |
Shrinkage rate | TD | ASTM D955 | 0.80 % |
Thermal performance | Test Condition | Test Method | VAMP TECH ITALY/DENYL HT 2010 Y |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ASTM D648A | 250 °C |
RTI Imp | UL 746 | 140 °C | |
RTI | UL 746 | 140 °C | |
RTI Elec | UL 746 | 140 °C |