Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC LUVOCOM® 50-8906 LEHVOSS Group
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1fU | 51 kJ/m² |
23°C | ISO 179/1eU | 55 kJ/m² |
Mechanical properties | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 6000 MPa | |
tensile strength | 断裂 | ISO 527-2 | 120 MPa |
Tensile strain | 屈服 | ISO 527-2 | 3.0 % |
Bending Strain | ISO 178 | 3.5 % | |
Flexural modulus | ISO 178 | 5000 MPa | |
bending strength | ISO 178 | 172 MPa |
Electrical performance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
insulation resistance | IEC 60167 | >1.0E+12 ohms |
flammability | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
UL flame retardant rating | UL 94 | HB |
physical property | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
Shrinkage rate | DIN 16901 | 0.20to0.40 % | |
Water absorption rate | 23°C,24hr | <0.15 % | |
density | ISO 1183 | 1.30 g/cm³ |
Thermal performance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 50-8906 |
---|---|---|---|
Continuous use temperature | UL 746B | 150 °C | |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 175 °C |
vicat | ISO 306/A | 180 °C | |
maximum service temperature | ShortTerm | 170 °C |