Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Ether Neostar™ FN005 Eastman Chemical Company
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
Impact strength of cantilever beam gap | -40°C | ASTM D256 | 50 J/m |
Supplementary Information | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
tear strength | 23°C | ASTM D1004 | 370 N |
hardness | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
Shore hardness | 邵氏D,23°C | ASTM D2240 | 55 |
邵氏A,23°C | ASTM D2240 | 95 |
film | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
elongation | TD:屈服,130µm | ASTM D882 | 26 % |
Water Vapor Transmission Rate | ASTMF372 | 130 g/m²/24hr | |
elongation | MD:屈服,130µm | ASTM D882 | 26 % |
Secant modulus | 正切,TD:130µm | ASTM D882 | 179 MPa |
正切,MD:130µm | ASTM D882 | 185 MPa | |
film thickness | 130 µm | ||
tensile strength | MD:屈服,130µm | ASTM D882 | 13.7 MPa |
OTr | 30°C,130µm | ASTM D1434 | 841 cm³/m²/24hr |
elongation | TD:断裂,130µm | ASTM D882 | 550 % |
tensile strength | TD:断裂,130µm | ASTM D882 | 22.6 MPa |
elongation | MD:断裂,130µm | ASTM D882 | 550 % |
tensile strength | MD:断裂,130µm | ASTM D882 | 23.7 MPa |
TD:屈服,130µm | ASTM D882 | 13.5 MPa |
Mechanical properties | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
coefficient of friction | ASTM D1894 | >1.0 | |
tensile strength | 断裂,23°C,2.00mm4 | ASTM D638 | 20.0 MPa |
Tensile modulus | 23°C | ASTM D638 | 170 MPa |
Flexural modulus | 23°C | ASTM D790 | 150 MPa |
tensile strength | 屈服,23°C,3.00mm,注塑3 | ASTM D638 | 14.0 MPa |
elongation | 屈服,23°C | ASTM D638 | 30 % |
断裂,23°C | ASTM D638 | 300 % |
elastomer | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
Kappa modulus | -70°C | ASTM D1043 | 930 MPa |
-28°C | ASTM D1043 | 240 MPa |
physical property | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 20 g/10min |
Water absorption rate | 23°C,24hr | ASTM D570 | 0.35 % |
intrinsic viscosity | 23°C | 内部方法 | 1.1 |
density | ASTM D792 | 1.13 g/cm³ |
Thermal performance | Test Condition | Test Method | Eastman Chemical Company/Neostar™ FN005 |
---|---|---|---|
Glass Transition Temperature | DSC | -3.00 °C | |
specific heat | 200°C8 | DSC | 3100 J/kg/°C |
melting temperature | ASTM D3418 | 207 °C | |
Fusion temperature | 23°C | ASTME793 | 27.0 kJ/kg |
specific heat | 100°C7 | DSC | 1800 J/kg/°C |
Linear coefficient of thermal expansion | MD:23°C | ASTM D696 | 1.5E-04 cm/cm/°C |
Crystallization peak temperature | DSC | DSC | 140 °C |
vicat | ASTM D15256 | 170 °C | |
thermal conductivity | 23°C | ASTMC177 | 0.19 W/m/K |
specific heat | 25°C7 | DSC | 1600 J/kg/°C |
brittle temperature | ASTM D746 | <-75.0 °C | |
specific heat | 175°C7 | DSC | 2300 J/kg/°C |
225°C9 | DSC | 2300 J/kg/°C | |
150°C7 | DSC | 2000 J/kg/°C |
Contact Us
Get App
Top