Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Phenolic Melaglas G5/G9 Accurate Plastics, Inc.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
Impact strength of cantilever beam gap | --6 | ASTM D256 | >430 J/m |
--5 | ASTM D256 | >530 J/m |
Supplementary Information | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
Viscosity | >770000 g |
hardness | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
Rockwell hardness | M级 | ASTM D785 | 120 |
Electrical performance | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
relative permittivity | IEC 60250 | 7.00 | |
Dissipation Factor | --7 | ASTM D150 | 0.017 |
--8 | ASTM D150 | 0.018 | |
dielectric strength | A | >60000 V | |
D48/50 | >55000 V | ||
arc resistance | ASTM D495 | 180 sec |
Mechanical properties | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
bending strength | 3.18mm3 | ASTM D790 | >262 MPa |
compressive strength | ASTM D695 | 483 MPa | |
bending strength | 3.18mm2 | ASTM D790 | >379 MPa |
physical property | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
Water absorption rate | 24hr,3.18mm | ASTM D570 | <0.70 % |
density | ASTM D792 | 1.90 g/cm³ |
Thermal performance | Test Condition | Test Method | Accurate Plastics, Inc./ Melaglas G5/G9 |
---|---|---|---|
TEMPERATURE | 140 °C |