Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEEK 1000G EVONIK GERMANY
VESTAKEEP®
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | EVONIK GERMANY/1000G |
---|---|---|---|
melting temperature | 343°C(11357) ℃(℉) | ||
Combustibility (rate) | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | EVONIK GERMANY/1000G |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 4.5 kg·cm/cm(J/M)ft·lb/in | |
tensile strength | ASTM D638/ISO 527 | 110 kg/cm²(MPa)[Lb/in²] | |
Charpy Notched Impact Strength | ASTM D256/ISO 179 | 5 kg·cm/cm(J/M)ft·lb/in |
Physical properties | Test Condition | Test Method | EVONIK GERMANY/1000G |
---|---|---|---|
shrinkage rate | ASTM D955 | LONG1%CROSS1.3% % | |
melt mass-flow rate | ASTM D1238/ISO 1133 | 80(380°C5kg值) g/10min |
processability | Test Condition | Test Method | EVONIK GERMANY/1000G |
---|---|---|---|
mold temperature | 360 °C |