Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA46 TC155 DSM HOLAND
Stanyl®
Home appliance components,Electronic and electrical components
Glass fiber reinforced,Thermal stability
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 2.5E-5 cm/cm/°C |
| Flow | ISO 11359-2 | 2.5E-5 cm/cm/°C | |
| thermal conductivity | --4 | ASTM E1461 | 5.0 W/m/K |
| --3 | ASTM E1461 | 1.0 W/m/K |
| mechanical properties | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 11000 Mpa | |
| Tensile strain | Break | ISO 527-2 | 0.60 % |
| tensile strength | Break | ISO 527-2 | 55.0 Mpa |
| Electrical performance | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Relative permittivity | 10.0 GHz | IEC 60250 | 3.89 |
| Physical properties | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Shrinkage rate | 横向Flow | ISO 294-4 | 0.30 % |
| Flow | ISO 294-4 | 0.30 % |
| impact performance | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 10 kJ/m² |
| 23°C | ISO 179/1eU | 10 kJ/m² |
| flammability | Test Condition | Test Method | DSM HOLAND/TC155 |
|---|---|---|---|
| Flammability level | UL 94 | V-0 |