Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PK LUVOCOM® 70-9046 LEHVOSS Group
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 70-9046 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 22 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1fU | 72 kJ/m² |
Electrical performance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 70-9046 |
---|---|---|---|
insulation resistance | IEC 60167 | >1.0E+11 ohms | |
Surface Resistivity | IEC 60093 | >1.0E+11 ohms |
Mechanical properties | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 70-9046 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 1400 MPa | |
tensile strength | 断裂 | ISO 527-2 | 50.0 MPa |
Tensile strain | 屈服 | ISO 527-2 | 40 % |
Flexural modulus | ISO 178 | 1200 MPa | |
bending strength | ISO 178 | 65.0 MPa |
physical property | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 70-9046 |
---|---|---|---|
Melt volume flow rate | 250°C/5.0kg | ISO 1133 | 5.00 cm³/10min |
Shrinkage rate | DIN 16901 | 1.6to2.2 % | |
Water absorption rate | 23°C,24hr | 0.15 % | |
density | ISO 1183 | 1.33 g/cm³ |
Thermal performance | Test Condition | Test Method | LEHVOSS Group/LUVOCOM® 70-9046 |
---|---|---|---|
Continuous use temperature | UL 746B | 90.0 °C | |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 100 °C |
vicat | ISO 306/A | 200 °C | |
maximum service temperature | ShortTerm | 120 °C |