Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PP Fiberfil® J-60/15/UV/HS Canada Fiberfil
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodCanada Fiberfil/Fiberfil® J-60/15/UV/HS
Rockwell hardnessASTM D785100-110 R
Mechanical propertiesTest ConditionTest MethodCanada Fiberfil/Fiberfil® J-60/15/UV/HS
bending strength23°CASTM D79065.0 MPa
Impact strength of cantilever beam gap23°CASTM D25642.7 J/m
屈服伸长率ASTM D6383.5 %
Tensile modulus23°CASTM D6382760 MPa
Flexural modulus23°CASTM D7902600 MPa
tensile strength 屈服,23°CASTM D63862.1 MPa
physical property Test ConditionTest MethodCanada Fiberfil/Fiberfil® J-60/15/UV/HS
melt mass-flow rate收缩率ASTM D9950.60 %
Shrinkage rateTD,3.17mmASTM D9950.50 %
Water absorption rate(23°C,24hr)ASTM D5700.030 %
densityASTM D7921.00 g/cm³
melt mass-flow rate℃/KgASTM D12388.0 g/10min
Shrinkage rateMD,3.17mmASTM D9950.40 %
Thermal performanceTest ConditionTest MethodCanada Fiberfil/Fiberfil® J-60/15/UV/HS
Heat distortion temperature1.80MPa未退火,HDTASTM D648138 °C
0.45MPa未退火,HDTASTM D648149 °C