Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 Tekumid 6 T/GF 50 TEKUMA Kunststoff GmbH
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
Impact strength of cantilever beam gap | 23°C | ASTM D256 | 140 J/m |
Mechanical properties | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
Tensile strain | 断裂 | ISO 527-2 | 1.7 % |
tensile strength | 屈服 | ISO 527-2 | 160 MPa |
Flexural modulus | ISO 178 | 6700 MPa | |
bending strength | ISO 178 | 250 MPa |
Electrical performance | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
dielectric strength | ASTM D149 | 21 kV/mm | |
Compared to the Leakage Tracking Index (CTI) | 解决方案A | IEC 60112 | PLC 1 |
解决方案B | IEC 60112 | PLC 2 |
flammability | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 600 °C |
UL flame retardant rating | 1.5mm | UL 94 | HB |
physical property | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
Shrinkage rate | MD | ASTM D955 | 0.20to0.30 % |
Water absorption rate | 平衡,23°C,50%RH | ASTM D570 | 0.80 % |
density | ASTM D792 | 1.56 g/cm³ |
Thermal performance | Test Condition | Test Method | TEKUMA Kunststoff GmbH/Tekumid 6 T/GF 50 |
---|---|---|---|
vicat | ISO 306/B120 | 215 °C | |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 200 °C |
Contact Us