Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 R 6 S GF 15 Germany Pal plast
--
--
Glass fiber reinforced material 15%, filler by weight, good impact resistance, good chemical resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | Germany Pal plast/R 6 S GF 15 |
|---|---|---|---|
| Melting temperature | ISO 3146 | 220 ℃ | |
| UL flame retardant rating | 1.60 mm | UL 94 | HB |
| Vicat softening temperature | ISO 306/B50 | 209 ℃ |
| mechanical properties | Test Condition | Test Method | Germany Pal plast/R 6 S GF 15 |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/1eU | 45 | |
| 23℃ | ISO 179/1eA | 6.5 kJ/m2 | |
| Tensile modulus | 23℃ | ISO 527-2/1A/1 | 5550 MPa |
| Tensile strain | 23℃,Break | ISO 527-2/1A/5 | 3.5 % |
| Tensile stress | 23℃,Break | ISO 527-2/1A/5 | 128 MPa |
| Electrical performance | Test Condition | Test Method | Germany Pal plast/R 6 S GF 15 |
|---|---|---|---|
| Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 1 |
| Physical properties | Test Condition | Test Method | Germany Pal plast/R 6 S GF 15 |
|---|---|---|---|
| density | ISO 1183 | 1.23 g/cm3 | |
| Water absorption rate | Saturation, 23℃ | ISO 62 | 7.8 % |
| Equilibrium, 23℃, 50%RH | 2.5 |