Product Info
Product Name
Brand Name
Usages
Properties
Certificates

ABS AE003 SABIC INNOVATIVE US
LNP™ STAT-KON™
Automotive Applications,Electrical applications,small home appliances
High mobility,High temperature resistan
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/AE003 |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 102 °C |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 104 °C | |
| 0.45MPa,Unannealed,64.0mmSpan | ISO 75-2/Bf | 104 °C | |
| 0.45MPa,Unannealed,3.20mm | ASTM D648 | 105 °C | |
| Linear coefficient of thermal expansion | TD:-30to30°C | ASTM D696 | 6.6E-05 cm/cm/°C |
| MD:-30to30°C | ASTM D696 | 1.9E-05 cm/cm/°C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/AE003 |
|---|---|---|---|
| Bending modulus | 50.0mmSpan | ASTM D790 | 12600 Mpa |
| ISO 178 | 12300 Mpa | ||
| bending strength | Yield,50.0mmSpan | ASTM D790 | 114 Mpa |
| Break,50.0mmSpan | ASTM D790 | 95.0 Mpa | |
| ISO 178 | 119 Mpa | ||
| elongation | Break | ASTM D638 | 0.90 % |
| Tensile modulus | ISO 527-2/1 | 11500 Mpa | |
| ASTM D638 | 12800 Mpa | ||
| Tensile strain | Break | ISO 527-2/5 | 0.90 % |
| tensile strength | Break | ISO 527-2/5 | 93.0 Mpa |
| Break | ASTM D638 | 92.0 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/AE003 |
|---|---|---|---|
| Surface resistivity | ASTM D257 | 2.0to4.0 ohms |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/AE003 |
|---|---|---|---|
| Shrinkage rate | TD:24hr | ASTM D955 | 0.55 % |
| MD:24hr | ASTM D955 | 0.10 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.28 % |
| 24hr,50%RH | ASTM D570 | 0.19 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/AE003 |
|---|---|---|---|
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 7.10 J |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5.7 kJ/m² |
| Multi axis Instrumented Impact Energy | ISO 6603-2 | 2.18 J | |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 16 kJ/m² |