plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA12 LX9012 EVONIK GERMANY
VESTAMID®
Cable sheath,Automotive Applications
Low temperature impact re,Resistance to stress crac,Fatigue resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Supplementary InformationTest ConditionTest MethodEVONIK GERMANY/LX9012
ISO ShortcutISO 1874PA12,EHL,22-010
thermal performanceTest ConditionTest MethodEVONIK GERMANY/LX9012
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B120 °C
1.8MPa,UnannealedISO 75-2/A45.0 °C
Linear coefficient of thermal expansionMD:23to55°CISO 11359-21.3E-04 cm/cm/°C
Melting temperatureISO 11357-3176 °C
Vicat softening temperature--ISO 306/B130 °C
--ISO 306/A170 °C
mechanical propertiesTest ConditionTest MethodEVONIK GERMANY/LX9012
Tensile modulusISO 527-21100 Mpa
Tensile strainYieldISO 527-25.0 %
BreakISO 527-2>50 %
tensile strengthYieldISO 527-237.0 Mpa
BreakISO 527-246.0 Mpa
Electrical performanceTest ConditionTest MethodEVONIK GERMANY/LX9012
Dielectric strengthIEC 60243-124 KV/mm
Dissipation factor23°C,100HzIEC 602500.053
23°C,1MHzIEC 602500.028
Relative permittivity23°C,1MHzIEC 602503.00
23°C,100HzIEC 602503.80
Volume resistivityIEC 600931E+14 ohms·cm
Physical propertiesTest ConditionTest MethodEVONIK GERMANY/LX9012
Shrinkage rateMDISO 294-41.0 %
TDISO 294-41.4 %
Water absorption rateEquilibrium,23°C,50%RHISO 620.80 %
Saturation,23°CISO 621.5 %
impact performanceTest ConditionTest MethodEVONIK GERMANY/LX9012
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
23°CISO 179/1eUNoBreak
flammabilityTest ConditionTest MethodEVONIK GERMANY/LX9012
UL flame retardant rating3.2mmUL 94HB
1.6mmUL 94HB