Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEEK 450G903 VICTREX UK
VICTREX®
Non specific food、Medical supplies、Nursing supplies
High rigidity、high strength、Chemical resistance、Semi crystalline、Good disinfection perform、Moderate liquidity、Food contact compliance、Ductility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
Suspended wall beam without notch impact strength | 23°C | ISO 180 | 无断裂 |
hardness | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
Shore hardness | 邵氏D,23°C | ISO 868 | 85 |
Mechanical properties | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
bending strength | 23°C7 | ISO 178 | 165 Mpa |
275°C | ISO 178 | 12.5 Mpa | |
3.5%应变,23°C | ISO 178 | 125 Mpa | |
Tensile strain | 断裂,23°C | ISO 527-2 | 30 % |
bending strength | 125°C | ISO 178 | 85.0 Mpa |
compression stress | 120°C | ISO 604 | 70.0 Mpa |
tensile strength | 屈服,23°C | ISO 527-2 | 98.0 Mpa |
Flexural modulus | 23°C | ISO 178 | 3800 Mpa |
Tensile modulus | 23°C | ISO 527-2 | 3900 Mpa |
compression stress | 23°C | ISO 604 | 125 Mpa |
bending strength | 175°C | ISO 178 | 19.0 Mpa |
Electrical performance | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
dielectric constant | 23°C,1kHz | IEC 60250 | 2.90 |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 4 | |
Volume resistivity | 125°C | IEC 60093 | 1E+15 ohms·cm |
23°C | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | 2.00mm | IEC 60243-1 | 24 KV/mm |
Dissipation Factor | 23°C,1MHz | IEC 60250 | 4E-03 |
Volume resistivity | 275°C | IEC 60093 | 1E+09 ohms·cm |
flammability | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
toxicity | COcontent | NES713 | 0.0740 |
CO2content | NES713 | 0.150 | |
Totalgases | NES713 | 0.220 | |
Limiting Oxygen Index | --13 | ISO 4589-2 | 35 % |
--12 | ISO 4589-2 | 24 % | |
Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 °C |
Filling analysis | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
melt viscosity | 400°C | ISO 11443 | 350 Pa·s |
physical property | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
Shrinkage rate | TD | ISO 294-4 | 1.3 % |
MD | ISO 294-4 | 1.0 % | |
spiral flow length | 内部方法 | 11.0 CM | |
Water absorption rate | 饱和,23°C | ISO 62 | 0.45 % |
100°C,饱和 | ISO 62 | 0.55 % |
Thermal performance | Test Condition | Test Method | VICTREX UK/450G903 |
---|---|---|---|
Linear coefficient of thermal expansion | MD:<143°C | ISO 11359-2 | 4.5E-05 cm/cm/°C |
Glass Transition Temperature | --8 | ISO 11357-2 | 143 °C |
Linear coefficient of thermal expansion | TD:>143°C | ISO 11359-2 | 1.4E-04 cm/cm/°C |
Glass Transition Temperature | --9 | ISO 11357-2 | 150 °C |
RTI | UL 746 | 240 °C | |
Linear coefficient of thermal expansion | TD:<143°C | ISO 11359-2 | 5.5E-05 cm/cm/°C |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/Af | 152 °C |
melting temperature | ISO 11357-3 | 343 °C | |
Linear coefficient of thermal expansion | MD:>143°C | ISO 11359-2 | 1.2E-04 cm/cm/°C |
thermal conductivity | 23°C10 | ISO 22007-4 | 0.29 W/m/K |
23°C11 | ISO 22007-4 | 0.32 W/m/K | |
RTI Imp | UL 746 | 180 °C | |
RTI Elec | UL 746 | 260 °C |