Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6 Nylfor® B2 MF/30 NATURALE SO.F.TER ITALY
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
Charpy Notched Impact Strength23°CISO 179/1eA4.0 kJ/m²
Impact strength of cantilever beam gap23°CASTM D25635 J/m
Electrical performanceTest ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 1
Mechanical propertiesTest ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
elongation断裂ASTM D6386.0 %
Tensile modulusASTM D6386300 MPa
tensile strength 断裂ASTM D63870.0 MPa
Flexural modulusASTM D7905500 MPa
flammabilityTest ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
UL flame retardant rating3.2mmUL 94HB
1.6mmUL 94HB
physical property Test ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
Shrinkage rate内部方法0.75 %
Water absorption rate平衡,23°C,50%RHISO 621.2 %
饱和,23°CISO 626.0 %
densityASTM D7921.36 g/cm³
Thermal performanceTest ConditionTest MethodSO.F.TER ITALY/Nylfor® B2 MF/30 NATURALE
Heat distortion temperature1.8MPa,未退火,HDTASTM D648110 °C

Contact Us

Get App

Top