Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC 144R-111 SABIC INNOVATIVE US
LEXAN™
Medical supplies,Nursing supplies,Non specific food
Flame retardant,transparent
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Rockwell hardness | M-Scale | ASTM D785 | 70 |
R-Scale | ASTM D785 | 118 |
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Ball Pressure Test | 123 to 127°C | IEC 60695-10-2 | 通过 |
Hot deformation temperature | 0.45 MPa, Unannealed, 4.00 mm, 100 mm Span10 | ISO 75-2/Be | 136 °C |
1.8 MPa, Unannealed, 4.00 mm, 100 mm Span10 | ISO 75-2/Ae | 125 °C | |
0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 137 °C | |
1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 132 °C | |
Linear coefficient of thermal expansion | 23 to 80°C,Flow | ISO 11359-2 | 7.0E-5 cm/cm/°C |
-40 to 95°C,Flow | ASTM E831 | 6.8E-5 cm/cm/°C | |
RTI | UL 746 | 130 °C | |
RTI Elec | UL 746 | 130 °C | |
RTI Imp | UL 746 | 130 °C | |
specific heat | ASTM C351 | 1250 J/kg/°C | |
thermal conductivity | -- | ASTM C177 | 0.19 W/m/K |
-- | ISO 8302 | 0.20 W/m/K | |
Vicat softening temperature | -- | ISO 306/B120 | 142 °C |
-- | ISO 306/B50 | 141 °C | |
-- | ASTM D152511 | 154 °C | |
-- | ISO 306/A50 | 153 °C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Bending modulus | --5 | ISO 178 | 2300 Mpa |
50.0 mm Span4 | ASTM D790 | 2340 Mpa | |
bending strength | Yield, 50.0 mm Span4 | ASTM D790 | 97.0 Mpa |
--5,6 | ISO 178 | 90.0 Mpa | |
elongation | Yield | ISO 527-2/50 | 6.0 % |
Yield3 | ASTM D638 | 7.0 % | |
Break3 | ASTM D638 | 130 % | |
Break | ISO 527-2/50 | 110 % | |
Taber abraser | 1000 Cycles, 1000 g, CS-17 Wheel | ASTM D1044 | 10.0 mg |
Tensile modulus | --2 | ASTM D638 | 2370 Mpa |
-- | ISO 527-2/1 | 2350 Mpa | |
tensile strength | Yield | ISO 527-2/50 | 63.0 Mpa |
Break | ISO 527-2/50 | 70.0 Mpa | |
Break3 | ASTM D638 | 68.0 Mpa | |
Yield3 | ASTM D638 | 62.0 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Compared to the anti leakage trace index | UL 746 | PLC 2 | |
Dielectric constant | 50 Hz | IEC 60250 | 2.70 |
50 kHz | ASTM D150 | 3.17 | |
60 Hz | ASTM D150 | 3.17 | |
1 MHz | IEC 60250 | 2.70 | |
1 MHz | ASTM D150 | 2.96 | |
60 Hz | IEC 60250 | 2.70 | |
Dielectric strength | 3.20 mm, in Oil | IEC 60243-1 | 17 KV/mm |
3.20 mm, in Air | ASTM D149 | 15 KV/mm | |
Dissipation factor | 1 MHz | ASTM D150 | 0.010 |
60 Hz | ASTM D150 | 9.0E-4 | |
50 Hz | IEC 60250 | 1.0E-3 | |
60 Hz | IEC 60250 | 1.0E-3 | |
50 Hz | ASTM D150 | 9.0E-4 | |
High arc combustion index | UL 746 | PLC 1 | |
High voltage arc tracing rate | UL 746 | PLC 2 | |
Hot wire ignition | UL 746 | PLC 2 | |
Surface resistivity | IEC 60093 | > 1.0E+15 ohms | |
Volume resistivity | -- | ASTM D257 | > 1.0E+17 ohms·cm |
-- | IEC 60093 | > 1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
melt mass-flow rate | 300°C/1.2 kg | ASTM D1238 | 11 g/10 min |
Melt Volume Flow Rate (MVR) | 300°C/1.2 kg | ISO 1133 | 10.0 cm3/10min |
Shrinkage rate | 3.20 mm,Flow | Internal Method | 0.50 - 0.70 % |
Specific volume | ASTM D792 | 0.830 cm³/g | |
Water absorption rate | 24 hr | ASTM D570 | 0.15 % |
Equilibrium, 23°C | ASTM D570 | 0.35 % | |
Equilibrium, 100°C | ASTM D570 | 0.58 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Dart impact | 23°C | ASTM D3029 | 169 J |
23°C, Energy at Peak | ASTM D3763 | 63.0 J | |
Impact strength of cantilever beam gap | ASTM D1822 | 577 kJ/m² | |
Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 3200 J/m |
flammability | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Extreme Oxygen Index | ASTM D2863 | 25 % | |
UL flame retardant rating | 1.5 mm | UL 94 | HB |
optical performance | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Refractive index | ASTM D542 | 1.586 | |
transmissivity | 2540 μm | ASTM D1003 | 88.0 % |
turbidity | 2540 μm | ASTM D1003 | 1.0 % |
injection | Test Condition | Test Method | SABIC INNOVATIVE US/144R-111 |
---|---|---|---|
Back pressure | 0.300 to 0.700 Mpa | ||
drying temperature | 120 °C | ||
drying time | 3.0 to 4.0 hr | ||
Exhaust hole depth | 0.025 to 0.076 mm | ||
Mold temperature | 70 to 95 °C | ||
Processing (melt) temperature | 295 to 315 °C | ||
Screw speed | 40 to 70 rpm | ||
Spray nozzle temperature | 290 to 310 °C | ||
Suggested injection volume | 40 to 60 % | ||
Suggested maximum moisture content | 0.020 % | ||
Temperature at the front of the material cylinder | 295 to 315 °C | ||
Temperature at the rear of the barrel | 270 to 295 °C | ||
Temperature in the middle of the barrel | 280 to 305 °C |