PA6 Nylux 6/ST2 KMI Group, Inc.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Electrical performanceTest ConditionTest MethodKMI Group, Inc./Nylux 6/ST2
Surface ResistivityIEC 600931E+13 Ω.cm
Volume resistivityIEC 600931E+15 Ω.cm
Mechanical propertiesTest ConditionTest MethodKMI Group, Inc./Nylux 6/ST2
Flexural modulus23°CISO 1781800 MPa
Tensile modulus23°CISO 527-22300 MPa
Impact strength of cantilever beam gap23°CISO 180/1A15 kJ/m²
tensile strength 23°CISO 527-255 MPa
elongation at break23°CISO 527-263 %
Flame retardant performanceTest ConditionTest MethodKMI Group, Inc./Nylux 6/ST2
UL flame retardant ratingUL -94HB .
physical property Test ConditionTest MethodKMI Group, Inc./Nylux 6/ST2
Water absorption rate(23°C,24hr)ISO 621.2 %
Shrinkage rateMDISO 294-41.7 %
densityISO 11831.10 g/cm³
Thermal performanceTest ConditionTest MethodKMI Group, Inc./Nylux 6/ST2
Linear coefficient of thermal expansion熔融温度ISO 3146222 °C