Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
LCP 6130LX NC010 DUPONT JAPAN
ZENITE®
--
enhance、Glass fiber reinforced、Filler: Glass fiber reinf、30%、Filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
LCP/DUPONT JAPAN/6130LX NC010
Shrinkage rate
TD
ISO294-4
%
0
Shrinkage rate
MD
ISO294-4
%
0
Mechanical performance
Test Condition
Test Method
Unit
LCP/DUPONT JAPAN/6130LX NC010
Impact strength of simply supported beam without notch
23°C
ISO179/1eU
kJ/m²
4
Tensile modulus
ISO527-2/1A/1
Mpa
1
tensile strength
断裂
ISO527-2/1A/5
Mpa
1
elongation
断裂
ISO527-2/1A/5
%
2
Bending modulus
23°C
ISO178
Mpa
1
bending strength
23°C
ISO178
Mpa
2
Compressive stress
ISO604
Mpa
1
Thermal performance
Test Condition
Test Method
Unit
LCP/DUPONT JAPAN/6130LX NC010
Hot deformation temperature
1.8MPa,未退火
ISO75-2/A
°C
2
Melting temperature
ISO11357-3
°C
3
Linear coefficient of thermal expansion
MD
ISO11359-2
cm/cm/°C
5
Linear coefficient of thermal expansion
TD
ISO11359-2
cm/cm/°C
6
Electrical performance
Test Condition
Test Method
Unit
LCP/DUPONT JAPAN/6130LX NC010
Surface resistivity
IEC60093
ohms
>
Dielectric strength
IEC60243-1
KV/mm
3
Leakage Trace Index
IEC60112
V
2
Volume resistivity
IEC60093
ohms·cm
>
flammability
Test Condition
Test Method
Unit
LCP/DUPONT JAPAN/6130LX NC010
Extreme Oxygen Index
ISO4589-2
%
5

Contact Us

Get App

Top