Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA12/PTFE SL-4530 SABIC INNOVATIVE US
LNP™ LUBRICOMP™
Electrical appliances,Plastic bag
lubrication,wear resistant
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/SL-4530 |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 146 °C |
0.45MPa,Unannealed,64.0mmSpan | ISO 75-2/Bf | 134 °C | |
1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 147 °C | |
0.45MPa,Unannealed,3.20mm | ASTM D648 | 150 °C | |
Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 1.1E-04 cm/cm/°C |
TD:-40to40°C | ISO 11359-2 | 1.1E-04 cm/cm/°C | |
TD:-40to40°C | ASTME831 | 1.1E-04 cm/cm/°C | |
MD:-40to40°C | ISO 11359-2 | 1.1E-04 cm/cm/°C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/SL-4530 |
---|---|---|---|
Bending modulus | ASTM D790 | 1380 Mpa | |
ISO 178 | 1300 Mpa | ||
bending strength | ISO 178 | 44.0 Mpa | |
elongation | Break | ASTM D638 | 24 % |
Yield | ASTM D638 | 18 % | |
Friction coefficient | Dynamic | ASTM D3702Modified | 0.23 |
Static | ASTM D3702Modified | 0.14 | |
Tensile modulus | ASTM D638 | 1380 Mpa | |
ISO 527-2/1 | 1580 Mpa | ||
Tensile strain | Yield | ISO 527-2 | 18 % |
Break | ISO 527-2 | 33 % | |
tensile strength | Yield | ASTM D638 | 37.9 Mpa |
Break | ISO 527-2 | 36.0 Mpa | |
Break | ASTM D638 | 35.2 Mpa | |
Yield | ISO 527-2 | 38.0 Mpa | |
Wear factor | Washer | ASTM D3702Modified | 13.5 10^-10in^5-min/ft-lb-hr |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/SL-4530 |
---|---|---|---|
Shrinkage rate | TD:24hr | ASTM D955 | 1.8-2.0 % |
TD:24hr | ISO 294-4 | 1.9 % | |
MD:24hr | ASTM D955 | 0.90-1.1 % | |
MD:24hr | ISO 294-4 | 1.0 % | |
Water absorption rate | 24hr,50%RH | ASTM D570 | 0.20 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/SL-4530 |
---|---|---|---|
Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 5.00 J |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 4.6 kJ/m² |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 7.80 J | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 48 kJ/m² |