Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT SK608 BK509 DUPONT USA
Cristin®
Automotive Applications,Electronic and electrical components
Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Supplementary Information | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 70.0 µgC/g | |
Odor | VDA270 | 3.00 |
thermal performance | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 222 °C |
1.8MPa,Unannealed | ISO 75-2/A | 207 °C | |
1.8 Mpa,Unannealed | ISO 75A-1 | 205 ℃ | |
Linear coefficient of thermal expansion | 平行Flow,23 to 55℃(73 to 130°F) | ISO 11359-1 | 0.000080 cm/cm/℃ |
垂直Flow,23 to 55℃(73 to 130°F) | ISO 11359-1 | 0.000080 cm/cm/℃ | |
TD | ISO 11359-2 | 8E-05 cm/cm/°C | |
MD | ISO 11359-2 | 2E-05 cm/cm/°C | |
Melting temperature | ISO 3146 | 225 ℃ | |
ISO 11357-3 | 225 °C | ||
UL flame retardant rating | 0.750 mm | UL 94 | HB |
1.50 mm | UL 94 | HB | |
3.00 mm | UL 94 | HB | |
Vicat softening temperature | ISO 306/B50 | 215 °C |
mechanical properties | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
Bending modulus | ISO 178 | 13300 Mpa | |
bending strength | ISO 178 | 210 Mpa | |
23℃ | ISO 178 | 235 MPa | |
Tensile modulus | ISO 527-2 | 14200 Mpa | |
23℃, 1.0 mm/min | ISO 527-1 | 14300 MPa | |
Tensile strain | 23℃,Break | ISO 527-1 | 2.1 % |
Break | ISO 527-2 | 2.0 % | |
tensile strength | Break | ISO 527-2 | 140 Mpa |
Tensile stress | 23 ℃, 5 mm/min,Break | ISO 527-1 | 160 MPa |
Electrical performance | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
Dielectric strength | IEC 60243-1 | 32 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 0.013 |
100Hz | IEC 60250 | 3.8E-03 | |
Relative permittivity | 100Hz | IEC 60250 | 4.10 |
1MHz | IEC 60250 | 3.90 | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
MediumDensity | 1.47 g/cm³ | ||
Shrinkage rate | MD | ISO 294-4 | 0.30 % |
Flow | ISO 294-4 | 0.3 % | |
TD | ISO 294-4 | 1.1 % | |
Across Flow | ISO 294-4 | 1.3 % | |
Top out temperature | 170 °C | ||
Water absorption rate | Sat/23C | ISO 62 | 0.3 % |
Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.10 % | |
23C/59RH | ISO 62 | 0.1 % | |
Saturation,23°C,2.00mm | ISO 62 | 0.30 % |
impact performance | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 65 kJ/m² |
23°C | ISO 179/1eU | 55 kJ/m² |
flammability | Test Condition | Test Method | DUPONT USA/SK608 BK509 |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | <100 mm/min |
Extreme Oxygen Index | ISO 4589-2 | 20 % | |
FMVSS flammability | FMVSS302 | B | |
UL flame retardant rating | 0.75mm | UL 94 | HB |
0.75mm | IEC 60695-11-10,-20 | HB | |
1.5mm | IEC 60695-11-10,-20 | HB | |
1.5mm | UL 94 | HB |