Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

POM CF302 KOLON KOREA
KOCETAL®
--
High rigidity,Conductive,Filler: Carbon fiber rein
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| Rockwell hardness | M-Scale | ASTM D785 | 87 |
| thermal performance | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648A | 160 °C |
| 0.45MPa,Unannealed | ASTM D648A | 164 °C | |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 6E-05 cm/cm/°C |
| Melting temperature | ASTM D1525 | 166 °C |
| mechanical properties | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| Bending modulus | 23°C | ASTM D790 | 9780 Mpa |
| bending strength | 23°C | ASTM D790 | 155 Mpa |
| elongation | Break,23°C | ASTM D638 | 2.5 % |
| tensile strength | 23°C | ASTM D638 | 105 Mpa |
| Electrical performance | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| Surface resistivity | ASTM D257 | 1E+03 ohms | |
| Volume resistivity | ASTM D257 | 1E+02 ohms·cm |
| Physical properties | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| melt mass-flow rate | 190°C/2.16kg | ASTM D1238 | 4.5 g/10min |
| Shrinkage rate | MD | ASTM D955 | 0.90 % |
| Water absorption rate | Equilibrium,23°C,60%RH | ASTM D570 | 0.22 % |
| flammability | Test Condition | Test Method | KOLON KOREA/CF302 |
|---|---|---|---|
| UL flame retardant rating | UL 94 | HB |