Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC GSH2020R2 MITSUBISHI ENGINEERING JAPAN
IUPILON™
Automotive Applications,electrical equipment
Glass fiber reinforced,Filler: Glass fiber reinf,20% filler by weight
TDSUL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/GSH2020R2 |
---|---|---|---|
Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 146 °C |
1.80MPaAnnealed | ISO 75-2/Af | 143 °C | |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6.3E-05 cm/cm/°C |
MD | ISO 11359-2 | 2.6E-05 cm/cm/°C |
flame retardant performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/GSH2020R2 |
---|---|---|---|
UL flame retardant rating | UL -94 | HB 0.40mm | |
UL -94 | HB 1.50mm | ||
UL -94 | HB 3.00mm |
mechanical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/GSH2020R2 |
---|---|---|---|
Bending modulus | 23°C | ISO 178 | 5800 Mpa |
bending strength | 23°C | ISO 178 | 160 Mpa |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 13 kJ/m² |
Tensile modulus | 23°C | ISO 527-2 | 6200 Mpa |
tensile strength | 23°C | ISO 527-2 | 104 Mpa |
Electrical performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/GSH2020R2 |
---|---|---|---|
Dielectric strength | IEC 60243-1 | 34 KV/mm | |
Volume resistivity | IEC 60093 | 1E+10 Ω.cm |
Physical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/GSH2020R2 |
---|---|---|---|
melt mass-flow rate | 300℃/1.2Kg | ISO 1133 | 8.00 cm3/10min |
Shrinkage rate | TD2.0mm | ISO 294-4 | 0.40 % |
MD2.0mm | ISO 294-4 | 0.20 % | |
Water absorption rate | (23°C,24hr) | ISO 62 | 0.11 % |