Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO EN185-701 SABIC INNOVATIVE US
NORYL™
electromagnetic shielding
Conductive,Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 113 |
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Hot deformation temperature | 0.45 MPa, Unannealed, 6.40 mm | ASTM D648 | 93.0 °C |
| 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 82.0 °C | |
| Linear coefficient of thermal expansion | -40 to 95°C,Flow | ASTM E831 | 7.4E-5 cm/cm/°C |
| RTI | UL 746 | 50.0 °C | |
| RTI Elec | UL 746 | 50.0 °C | |
| RTI Imp | UL 746 | 50.0 °C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Bending modulus | 100 mm Span | ASTM D790 | 2270 Mpa |
| bending strength | Yield, 100 mm Span | ASTM D790 | 67.0 Mpa |
| elongation | Break | ASTM D638 | 50 % |
| tensile strength | Yield | ASTM D638 | 42.0 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Arc resistance | ASTM D495 | PLC 7 | |
| Compared to the anti leakage trace index | UL 746 | PLC 2 | |
| Dielectric constant | 50 kHz | ASTM D150 | 2.80 |
| 60 Hz | ASTM D150 | 2.80 | |
| Dielectric strength | 3.20 mm, in Oil | ASTM D149 | 25 KV/mm |
| Dissipation factor | 60 Hz | ASTM D150 | 4.0E-3 |
| 50 Hz | ASTM D150 | 4.0E-3 | |
| 1 MHz | IEC 60250 | 3.5E-3 | |
| High arc combustion index | UL 746 | PLC 0 | |
| High voltage arc tracing rate | UL 746 | PLC 4 | |
| Hot wire ignition | UL 746 | PLC 1 |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| density | ASTM D792 | 1.08 g/cm³ | |
| Water absorption rate | 24 hr | ASTM D570 | 0.070 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Dart impact | -30°C | ASTM D3029 | 24.0 J |
| -40°C | ASTM D3029 | 13.0 J | |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 390 J/m |
| -40°C | ASTM D256 | 160 J/m |
| flammability | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| Radiation board grade | UL Unspecified | TRUE | |
| UL flame retardant rating | 3.0 mm | UL 94 | V-0 |
| 1.5 mm | UL 94 | V-1 |
| squeeze out | Test Condition | Test Method | SABIC INNOVATIVE US/EN185-701 |
|---|---|---|---|
| drying temperature | 90 to 100 °C | ||
| drying time | 2.0 to 4.0 hr | ||
| Joint temperature | 205 °C | ||
| Melt Temperature | 195 to 210 °C | ||
| Oral mold temperature | 205 °C | ||
| Suggested maximum moisture content | 0.020 % | ||
| Temperature in Zone 1 of the material cylinder | 170 °C | ||
| Temperature in Zone 2 of the material cylinder | 170 °C | ||
| Temperature in Zone 3 of the material cylinder | 190 °C | ||
| Temperature in Zone 4 of the material cylinder | 190 °C |