plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6 K225-KV ENVALIOR JIANGSU
Akulon® 
Electrical applications,household electrical appliances
Glass fiber reinforced,High rigidity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

thermal performanceTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Melting temperatureISO 11357-3220 °C
mechanical propertiesTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Nominal tensile fracture strainISO 527-24.0 %
Tensile modulusISO 527-24200 Mpa
Tensile strainYieldISO 527-23.0 %
tensile strengthYieldISO 527-270.0 Mpa
Electrical performanceTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Compared to the anti leakage trace indexIEC 60112PLC 0
Dielectric strengthIEC 60243-130 KV/mm
Dissipation factor1MHzIEC 602500.020
100HzIEC 602509E-03
Relative permittivity100HzIEC 602503.30
1MHzIEC 602503.20
Surface resistivityIEC 60093-- ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
Physical propertiesTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Shrinkage rateMDISO 294-41.0 %
TDISO 294-41.0 %
Water absorption rateEquilibrium,23°C,50%RHISO 622.0 %
Saturation,23°CISO 627.5 %
impact performanceTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Impact strength of simply supported beam without notch23°CISO 179/1eU40 kJ/m²
flammabilityTest ConditionTest MethodENVALIOR JIANGSU/K225-KV
Burning wire flammability index3.0mmIEC 60695-2-12960 °C
0.38mmIEC 60695-2-12960 °C
Hot filament ignition temperature0.38mmIEC 60695-2-13930 °C
3.0mmIEC 60695-2-13850 °C
UL flame retardant rating3.0mmIEC 60695-11-10,-20V-2
0.38mmIEC 60695-11-10,-20V-2