Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA+Olefin NEALID XG100 AD MAJORIS FRANCE
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Impact strength of simply supported beam without notchISO 17944 kJ/m²
Charpy Notched Impact StrengthISO 17911 kJ/m²
Electrical performanceTest ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Surface ResistivityDIN 534821E+15 ohms
Compared to the Leakage Tracking Index (CTI)解决方案AIEC 60112PLC 0
Volume resistivityDIN 534821E+15 ohms·cm
Mechanical propertiesTest ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Tensile modulusISO 527-24400 MPa
tensile strength 断裂ISO 527-2120 MPa
Tensile strain断裂ISO 527-23.5 %
Flexural modulusISO 1783750 MPa
bending strengthISO 178135 MPa
flammabilityTest ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Burning wire flammability index2.0mmIEC 60695-2-12650 °C
UL flame retardant rating1.6mmUL 94HB
physical property Test ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Shrinkage rate0.70to1.2 %
Water absorption rate平衡,23°C,50%RH1.3 %
densityISO 11831.14 g/cm³
Thermal performanceTest ConditionTest MethodAD MAJORIS FRANCE/NEALID XG100
Heat distortion temperature0.45MPa,未退火,HDTISO 75-2/B190 °C
1.8MPa,未退火,HDTISO 75-2/A180 °C
melting temperatureISO 3146220 °C

Contact Us

Get App

Top