Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 54G43 NC ASAHI JAPAN
Leona™
Automotive Applications,Gears,Application in the automotive field,component,Industrial applications,Fabric,Fan,Railway sleeper insulation,Office Furniture
high strength,High rigidity,Filler: Glass fiber reinf,Enhanced strength,Rigidity and impact resis,43% filler by weight,Glass fiber content is 43,Good appearance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Rockwell hardness | M-Sale | ASTM D785 | 93 |
M-Sale | ISO 2039-2 | 93 | |
R-Sale | ISO 2039-2 | 118 | |
R-Sale | ASTM D785 | 118 |
Basic Performance | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Water absorption rate | 湿 | 1.6 % |
thermal performance | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 240 °C |
0.45MPa,Unannealed | ISO 75-2/B | 245 °C | |
1.82MPa,干 | ASTM D-648 | 240 °C | |
1.8MPa,Unannealed | ISO 75-2/A | 230 °C | |
0.45MPa,Unannealed | ASTM D648 | 250 °C | |
0.46MPa,干 | ASTM D-648 | 250 °C | |
UL flame retardant rating | 干 | UL 94 | HB |
mechanical properties | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Bending modulus | ASTM D790 | 11000 Mpa | |
23°C | ISO 178 | 10600 Mpa | |
bending strength | 干(湿) | ASTM D-790 | 304(177) Mpa |
23°C | ISO 178 | 290 Mpa | |
ASTM D790 | 304 Mpa | ||
elongation | Break | ASTM D638 | 3.0 % |
Elongation at Break | 干(湿) | ASTM D-638 | 3(4) % |
flexural coefficient | 干(湿) | ASTM D-790 | 11.0(5.9) GPa |
Impact strength of cantilever beam gap | 干(湿) | ASTM D-256 | 147(226) J/m |
Rockwell hardness | 干(湿) | ASTM D-785 | 93(-) M Scale |
干(湿) | ASTM D-785 | 118(-) R scale | |
Tensile modulus | 23°C | ISO 527-2 | 12200 Mpa |
Tensile strain | Break,23°C | ISO 527-2 | 4.0 % |
tensile strength | Break,23°C | ISO 527-2 | 200 Mpa |
干(湿) | ASTM D-638 | 186(132) Mpa | |
ASTM D638 | 186 Mpa |
Electrical performance | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Compared to the anti leakage trace index | 3.00mm | IEC 60112 | PLC 0 |
Dielectric strength | IEC 60243-1 | 32 KV/mm | |
ASTM D149 | 32 KV/mm | ||
Surface resistivity | ASTM D257 | 1E+15 ohms | |
IEC 60093 | 1E+15 ohms | ||
Volume resistivity | ASTM D257 | 1E+15 ohms·cm | |
23°C | IEC 60093 | 1E+15 ohms·cm |
Physical properties | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Shrinkage rate | MD | Internal Method | 0.30 % |
吸水率(Saturation,23°C) | Internal Method | -- % | |
干 | 旭化成方法 | 0.3/0.7 % | |
TD | Internal Method | 0.70 % | |
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | -- % |
impact performance | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179 | 99 kJ/m² |
flammability | Test Condition | Test Method | ASAHI JAPAN/54G43 NC |
---|---|---|---|
UL flame retardant rating | 0.75mm | UL 94 | HB |