plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6 BG-30/2 EMS-CHEMIE SWITZERLAND
Grilon® 
Home appliance components,Automotive sector,Automotive interior parts,Electronic field,Electrical field,automotive industry ,electrical machinery,electron,motion,Leisure and mechanical engineering fields
Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Basic PerformanceTest ConditionTest MethodEMS-CHEMIE SWITZERLAND/BG-30/2
densitydryISO 11831.35 dry
Water absorption rate23℃ISO 627 %
23℃/50%rhISO 622 %
thermal performanceTest ConditionTest MethodEMS-CHEMIE SWITZERLAND/BG-30/2
Hot deformation temperature8.00MPa,dryISO 75135 °C
1.80MPa,dryISO 75200 °C
Linear coefficient of thermal expansion23-55℃,dry,Across FlowISO 113590.3
23-55℃,dry(Across Flow)ISO 113591.1
Maximum operating temperaturelong term,dryISO 2578100-120 °C
short term,dryISO 2578200 °C
Melting temperatureDSC,dryISO 11357222 °C
UL flame retardant rating0.8mmISO 1210HB
mechanical propertiesTest ConditionTest MethodEMS-CHEMIE SWITZERLAND/BG-30/2
Ball Pressure Testdry,condISO 2039-1210(100) Mpa
Elongation at Break5mm/min(dry,cond)ISO 5273.5(6.5) %
Impact strength of cantilever beam gapCharpy,-30℃(dry,cond)ISO 179/1eU70(70) KJ/m
Charpy,-30℃(dry,cond)ISO 179/1eA9(9) KJ/m
Charpy,23℃(dry,cond)ISO 179/1eA12(20) KJ/m
Charpy,23℃(dry,cond)ISO 179/1eU85(95) KJ/m
Tensile modulus1mm/min,(dry,cond)ISO 52710000(6500) Mpa
tensile strength5mm/min(dry,cond),BreakISO 527190(110) Mpa
Electrical performanceTest ConditionTest MethodEMS-CHEMIE SWITZERLAND/BG-30/2
Arc resistancecondIEC 60112550
Dielectric strengthdry,condIEC 60243-134(31) KV/mm
Surface resistivitycondIEC 6009310 Ω
Volume resistivitydry,condIEC 6009310 Ω.cm
Physical propertiesTest ConditionTest MethodEMS-CHEMIE SWITZERLAND/BG-30/2
Shrinkage ratetrans,Across Flow,dryISO 2940.55 %
long,Across FlowISO 2940.10 %