Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PP Copolymer Generic PP Copolymer - Carbon Fiber Generic
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Generic/Generic PP Copolymer - Carbon Fiber |
---|---|---|---|
Impact strength of cantilever beam gap | 23℃ | J/m | 0.050to0.135 |
Mechanical properties | Test Condition | Test Method | Generic/Generic PP Copolymer - Carbon Fiber |
---|---|---|---|
bending strength | 23℃ | 89.66to200.0 Mpa | |
elongation | 断裂,23℃ | % | 2.5to2.8 |
tensile strength | 屈服,23℃ | 6.9to120.0 Mpa | |
Flexural modulus | 23℃ | 3620.69to9310.34 Mpa |
physical property | Test Condition | Test Method | Generic/Generic PP Copolymer - Carbon Fiber |
---|---|---|---|
Shrinkage rate | MD:23℃ | mm/mm | 38.1E-3-127.0E-3 |
density | 1.10to1.23 |
Thermal performance | Test Condition | Test Method | Generic/Generic PP Copolymer - Carbon Fiber |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | °C | 148to165 |