Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 9A22115 HR 4Plas
--
--
Filler, reinforcement material, glass fiber reinforcement material, 15%, filler by weight characteristics, hydrolysis resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 245 °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 245 °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 240 °C | |
| 1.8 MPa, Unannealed | ISO 75-2/A | 240 °C | |
| Melting temperature | ISO 11357 | 262 °C | |
| Vicat softening temperature | ISO 306/B | 245 °C |
| mechanical properties | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 6.0 kJ/m² |
| -30°C | ISO 180/1A | 5.0 kJ/m² | |
| Tensile modulus | 23°C | ISO 527-2/5 | 5750 MPa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 3.0 % |
| Break, 23°C | ISO 527-2/5 | 3.0 % | |
| tensile strength | Break, 23°C | ISO 527-2/5 | 120.0 MPa |
| Break,23°C | ISO 527-2/5 | 120 MPa |
| Electrical performance | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
| Surface resistivity | IEC 60093 | 1E+13 ohms | |
| Volume resistivity | IEC 60093 | 1E+15 ohms·cm |
| other | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Burning wire flammability index | 2.00 mm | IEC 60695-2-12 | 650 °C |
| UL flame retardant rating | 0.750 mm | UL 94 | HB |
| 1.60 mm | UL 94 | HB |
| Physical properties | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| density | ISO 1183 | 1.23 g/cm³ | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 2.3 % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 2.3 % | |
| water content | ISO 960 | <2000 ppm |
| impact performance | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.0 kJ/m² |
| 23°C | ISO 180/1A | 6.0 kJ/m² |
| flammability | Test Condition | Test Method | 4Plas/9A22115 HR |
|---|---|---|---|
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 650 °C |
| UL flame retardant rating | 3.2mm | UL 94 | HB |
| 1.6mm | UL 94 | HB |