Material Comparison
Add Comparison Model
Select Products for Comparison (1/4)
Highlight Differences
Hide Same
Product Name / Manufacturer / Model
Grade
Reference Price
| mechanical properties | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
|---|---|---|---|
| Compressive modulus | ASTM D695 | 1730 Mpa | |
| elongation | Break | ASTM D638 | 60 % |
| bending strength | Yield | ASTM D790 | 91.0 Mpa |
| compressive strength | ASTM D695 | 98.9 Mpa | |
| shear strength | ASTM D732 | 62.7 Mpa | |
| Tensile modulus | ASTM D638 | 2340 Mpa | |
| tensile strength | Break | ASTM D638 | 69.6 Mpa |
| Yield | ASTM D638 | 69.6 Mpa | |
| Bending modulus | ASTM D790 | 2410 Mpa | |
| elongation | Yield | ASTM D638 | 7.2 % |
| Poisson's ratio | ASTME132 | 0.42 | |
| thermal performance | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| thermal conductivity | ASTMC177 | 0.35 W/m/K | |
| Glass transition temperature | ASTME1356 | 220 °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 214 °C |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 5.6E-05 cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 207 °C |
| flammability | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| UL flame retardant rating | 0.75mm | UL 94 | V-0 |
| Extreme Oxygen Index | ASTM D2863 | 38 % | |
| Physical properties | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| melt mass-flow rate | ASTM D1238 | 14to20 g/10min | |
| density | ASTM D792 | 1.30 g/cm³ | |
| Water absorption rate | 24hr | ASTM D570 | 0.37 % |
| Shrinkage rate | MD | ASTM D955 | 0.70 % |
| Electrical performance | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| Dielectric constant | 1kHz | ASTM D150 | 3.40 |
| Volume resistivity | ASTM D257 | 9E+15 ohms·cm | |
| Dielectric constant | 60Hz | ASTM D150 | 3.44 |
| Dielectric strength | ASTM D149 | 14 KV/mm | |
| optical performance | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| Refractive index | ASTM D542 | 1.672 | |
| impact performance | Test Condition | Test Method | SOLVAY USA/R-5100 GY1037 |
| Impact strength of cantilever beam gap | ASTM D1822 | 399 kJ/m² | |
| ASTM D256 | NoBreak J/m |