Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 FR50 BK505 DUPONT USA
Zytel®
Fitness equipment,Automotive sector,Electrical field,Electronic field,Electrical appliances
Flame retardant,Glass fiber reinforced
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| Supplementary Information | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| EmissionofOrganicCompounds | VDA277 | 4.70 µgC/g | |
| Odor | VDA270 | 4.50 |
| thermal performance | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| Combustibility (rate) | UL 94 | V-0 | |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 242 ℃(℉) |
| 1.8MPa,Unannealed | ISO 75-2/A | 242 °C | |
| 1.8 MPa, Unannealed | ISO 75-2/A | 240 °C | |
| Linear coefficient of thermal expansion | TD:-40to23°C | ISO 11359-2 | 6.9E-05 cm/cm/°C |
| MD:-- | ISO 11359-2 | 2.1E-05 cm/cm/°C | |
| MD:-40to23°C | ISO 11359-2 | 2.5E-05 cm/cm/°C | |
| MD:55to160°C | ISO 11359-2 | 1.2E-05 cm/cm/°C | |
| TD:-- | ISO 11359-2 | 7.9E-05 cm/cm/°C | |
| TD:55to160°C | ISO 11359-2 | 1.1E-04 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 262 °C | |
| 260 ℃(℉) |
| mechanical properties | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| Bending modulus | ISO 178 | 9410 Mpa | |
| ASTM D790/ISO 178 | 9410 kg·cm/cm(J/M)ft·lb/in | ||
| Elongation at Break | ASTM D638/ISO 527 | 2.1 % | |
| Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 7.9 kg·cm/cm(J/M)ft·lb/in | |
| Tensile modulus | ASTM D638/ISO 527 | 10640 kg/cm²(MPa)[Lb/in²] | |
| ISO 527-2 | 10200 Mpa | ||
| Tensile strain | Break | ISO 527-2 | 2.6 % |
| tensile strength | ASTM D638/ISO 527 | 158 kg/cm²(MPa)[Lb/in²] | |
| Break | ISO 527-2 | 170 Mpa |
| Electrical performance | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 | |
| Dielectric strength | 2.00 mm | IEC 60243-1 | 24 KV/mm |
| Surface resistivity | IEC 62631-3-2 | -- ohms | |
| Volume resistivity | IEC 62631-3-1 | > 1.0E+13 ohms·m |
| other | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| characteristic | PA66.25%玻维增强.阻燃.注射成型 |
| Physical properties | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| density | ASTM D792/ISO 1183 | 1.60 | |
| Shrinkage rate | MD | ISO 294-4 | 0.30 % |
| 横向Flow | ISO 294-4 | 0.80 % | |
| ASTM D955 | 0.3-0.7 % | ||
| Flow | ISO 294-4 | 0.30 % | |
| TD | ISO 294-4 | 0.70 % | |
| Top out temperature | 210 °C | ||
| Water absorption rate | 24 hr, 23°C, 2.00 mm | ISO 62 | 0.60 % |
| impact performance | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -40°C | ISO 179/1eU | 50 kJ/m² |
| -30°C | ISO 179/1eU | 50 kJ/m² | |
| 23°C | ISO 179/1eU | 60 kJ/m² |
| flammability | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| Burning rate | 1.00mm | ISO 3795 | <100 mm/min |
| Extreme Oxygen Index | ISO 4589-2 | 35 % | |
| FMVSS flammability | FMVSS302 | B | |
| UL flame retardant rating | 0.75mm | UL 94 | V-0 |
| 0.75mm | IEC 60695-11-10,-20 | V-0 | |
| 1.5mm | IEC 60695-11-10,-20 | V-0 | |
| UL 94 | V-0 | ||
| 1.5mm | UL 94 | V-0 |
| injection | Test Condition | Test Method | DUPONT USA/FR50 BK505 |
|---|---|---|---|
| drying temperature | 80 °C | ||
| Drying time - hot air dryer | 2.0 to 4.0 hr | ||
| Hold Pressure Time | 3.00 s/mm | ||
| Maintain pressure | Drying Recommended | yes | |
| 50.0 to 100 Mpa | |||
| Maximum Screw Tangential Speed | 12 m/min | ||
| Melt Temperature, Optimum | 290 °C | ||
| Mold temperature | 70 to 120 °C | ||
| Mold Temperature, Optimum | 100 °C | ||
| Processing (melt) temperature | 280 to 300 °C | ||
| Suggested maximum moisture content | 0.20 % |